GQ-1129/1129D Signal level meter The instrument adopts the all-number display, the readings on the measuring instrument are clear and precise, and owing to the introduction of the micro processing unit, therefore, it makes its functions stronger, the precision higher, operation more flexible and convenient. The large screen figure monitor is very convenient to measure the main technical targets of CATV system. It has the functions such as the single-channel, multi-channel, all-band scanning, difference-carrying measurement, signal-to-noise ratio (SNR, S/N) measurement and spectrum analysis frequency analysis etc.
Tuning range: from 5M~862MHz
Tuning mode: by channels or by frequency
Level measurement
Analogue channels Measurement
IF bandwidth: 280kHz+50kHz
Input impedance: 75ohm
Measuring range: from 25 to 120 dBuv
Accuracy: +2dB (from 0 to 400C)
Digital channels Measurement
MER (modulation error ratio) measurement range: 19~35dB for 64 QAM
Accuracy : +2dB
BER (bit error rate) measured before RS decoding measurement range: 10E-2 to 10E-8
Symbol rate: 1MS/S-7MS/S
Modulations type: 16/32/64/128/256QAM DVB-C/ITU-TJ. 83-AnnexA
Bandwidth: 8MHz
Frequency tuner: 100 KHz
Measuring range: from 40 to 120 dBuv
Accuracy: +3dB (from 0 to 400C)
MODEL NO |
Frequency
Range |
Constellation diagram |
Features |
Main Indexes |
LCD | |
GQ128 |
46~870MHz |
No |
*Handhold Design *Level and V/A *Tilt and C/N measure *Channel spectrum scanning *Spectrum analysis *Trunk Voltage *Channel and single frequency mode |
*Signal Level Measurement Range 30dBμV ~ 120dBμV Level Precision 1. 5dB *Spectrum Analysis Span 4. 5MHz, 9MHz, 18MHz 36MHz, 128MHz *Frequency 46MHz~870MHz 5MHz~870MHz *Digital Channel Power Bandwidth 0. 28MHz~9. 99MHz |
128 * 128 LCD
| |
GQ128D |
5~870MHz |
MODEL NO |
Frequency
Range |
Constellation diagram |
Features |
Main Indexes |
LCD |
GQ1128 |
46~870MHz |
No |
*Handhold Design *Channel spectrum scanning *spectrum analysis *Limit test and Auto test *PC Toolbox Software(option) *Support USB device and RS-232 connection *Analog, Digital, FM and Dual channel measurement *Support QAM 32 64 128/ITU-TJ. 83 Annex A/B/C *Channel Power, MER, BER *Constellation Diagram (option) |
*Signal Level Measurement Range 30dBμV ~ 120dBμV Level Precision ±1. 5dB *Spectrum Analysis Span 4. 5MHz, 9MHz, 18MHz 36MHz, 128MHz *Frequency 46MHz~870MHz( 5MHz~870MHz *Digital Channel Power Bandwidth 0. 28MHz~9. 99MHz |
128 * 128 LCD
|
GQ1128D |
5~870MHz | ||||
GQ1129 |
46~870MHz |
Yes | |||
GQ1129D |
5~870MHz |