SW-1 Series

RATED VOLTAGE : 250V, ac (and 125V)
RATED CURRENT : 10A (and 15A)
INTERRUPTING CURRENT : 250V, ac 15A
TRANSIENT OVERLOAD TEST CURRENT : dc current pulses, with an amplitude 150 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.

SW-2 Series
RATED VOLTAGE : 250V, ac
RATED CURRENT : 2A
INTERRUPTING CURRENT : 250V, ac 3A
TRANSIENT OVERLOAD TEST CURRENT :
dc current pulses, with an amplitude 30A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.


SW-3 Series

RATED VOLTAGE : 250V, ac
RATED CURRENT : 15A
INTERRUPTING CURRENT : 250V, ac 22. 5A
TRANSIENT OVERLOAD TEST CURRENT :
dc current pulses, with an amplitude 225 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.

SW-5 Series

RATED VOLTAGE : 250V, ac (and 125V -*)
RATED CURRENT : 5A (and 6A -*)
INTERRUPTING CURRENT : 250V, ac 7. 5A
TRANSIENT OVERLOAD TEST CURRENT :
dc current pulses, with an amplitude 75 A and a duration of 3 ms with 10 s intervals, are applied for 100 successive cycles through the current path.


SW-6 Series

RATED VOLTAGE : 50V, dc
RATED CURRENT : 2A or 4A
INTERRUPTING CURRENT : 50V, dc 3A or 6A