Elevator load sensor (LC-59X/ LC-58S)
Main Features:
Easy to install and adjust
Detect the elevator overload
Based on Hall Effect
Output switch signals
Technical Parameters:
|
Items |
LC-58S/LC-59X |
|
Sensing Distance |
2-9mm±15% |
|
Differential Travel |
15% |
|
sensing Object |
Magnetic Metal |
|
Response Frequency |
0.2KHz |
|
Input Voltage |
12 to 24VDC |
|
Output Current |
Relay output |
|
Indicator |
Green LED |
|
Temperature Influence |
-10~70℃,Max. Of sensing distance at 23℃ in the temperature rang±5% |
|
Voltage Influence |
±2.5% max. Of sensing distance in the rated voltage range±10% |
|
Insulation Resistance |
50MΩ |
|
Dielectric Strength |
500VAC at 50/60Hz for 1 min |
|
Connection Method |
Wire leading models(standard length 1.2m) |
Elevator Leveling Sensor (EM-11S/EMD-51S)
Main Features:
Easy to install and adjust
Detect the elevator leveling
Based on Hall Effect
Short-circuit Protection
Technical Parameters:
|
Items |
EM -11S/EMD-51S |
|
Sensing Distance |
10-30mm±15% |
|
Differential Travel |
15% |
|
Sensing Object |
Magnetic plastic |
|
Response Frequency |
0.5KHz |
|
Input Voltage |
10 to 30VDC |
|
Output Current |
≤180mA |
|
Indicator |
Green LED |
|
Temperature Influence |
-10~70℃,Max. Of sensing distance at 23℃ in the temperature rang±5% |
|
Voltage Influence |
±2.5% max. Of sensing distance in the rated voltage range±10% |
|
Insulation Resistance |
50MΩ |
|
Dielectric Strength |
500VAC at 50/60Hz for 1 min |
|
Connection Method |