Specifications

Pressure Switch 
Specifications: ☆ For use with fluorinated refrigerants as well as with a air and water.(Allowable Fluid Temp.:-10℃~+110℃) ☆ Various contact functions available. ☆ With SPDT contact mechanism. ☆ Renovated micro-switch structure ensures the reliable switch function. ☆ Manual-controlled and no use of other instruments to have a function test. ☆ Flexible mounting plate suits various kinds of application.

 

Model
Range(bar)
Differential(bar)
Factory Setting(bar)
Max. Bellows Press(bar)
 
Min
Max
Min
Max
OFF
ON
 
HLP503
-0.7
3
0.2
1.5
2
1
16.5
 
HLP506
-0.7
6
0.6
4
3
2
16.5
 
HLP506M
-0.7
6
Duplicate voltage disparity≤1
3
Manual Reset
16.5
 
HLP110
1
10
1
3
6
5
16.5
 
HLP516
5
16
1
4
10
8
35
 
HLP520
5
24
2
5
16
13
35
 
HLP530D
5
30
5
10
20
15
35
 
HLP530
8
30
Fixed3-5
20
15-17
35
 
HLP530M
8
30
Duplicate voltage disparity≤4
20
Manual Reset
35