Product Main

Specifications

Digital controller with large scale integrated circuit,
LCD temperature display and multi-functional diagnostic function,
User-machine conversation, shows current temperature and working status of the system including frostbit-proof and anti-freezing status, normal heating status, multi-timing program setting status, diagnostic failure status.
Environment friendly, CO(a=1)exaust,0.017%
Heat efficiency and energy-saving, 90% of heat efficiency, Ⅱ grade,
Remote controller and room temperature thermostat is optional,
Constant sanitary hot water temperature with water flow stabilization sensor.
Closed and pump forced waterway circulation,
The main integrated controller is compatible to various architecture heating and ventilation system including radiators,fin, floor heating,fan coil,
Multi-timing program for hourly,daily,weekly
 
 
COMFORTABLE -THE CONCEPT OF AILUNSI CENTRAL HEATING SYSTEM
  • Ailunsi persists in technical innovation and development creat comfortable, economic, safe, efficient personalized life.
  • Ailunsi central heating gas fired water boilers are designed with aesthetic outlook, with perfect functions to provide both residential heating and domestic hot water for architecture and building heating engineering, hotel integrated heating, individual residential house, luxury apartment, satisfying various requirements of room heating, floor heating and sanitary use of hot water.
  • Illuminated digital display controller panel has convenient multe-timing setting for any hour or any periods in 24 hours or in any days in lots of several weeks, providing best selection of room heating.
  • Environment friendly and energy-saving is the real repaying to customers and users from the economical operation of Ailunsi central heating system.
 
Technical parameter of Ailunsi gas boilers
Model JLG18 JLG20 JLG24 JLG30
Type of fuel gas LPG      NG LPG      NG LPG      NG LPG      NG
Rated gas pressure Pa 2800      2000 2800      2000 2800      2000 2800      2000
Rated heat input kW 18 20 24 30
Heating efficiency % 90% 90% 90% 90%
Rated hot water production △t=25k L/min 9 10 12 15
Rated heat output kW 16.7 18.4 22.4 27.8
Temperature Range of heating system 30-80(radiators) 30-80(radiators) 30-80(radiators) 30-80(radiators)
Temperature Range of heating system 25-60(floor) 25-60(floor) 25-60(floor) 25-60(floor)
Maximal pressure of heating system bar 3(0.3Mpa) 3(0.3Mpa) 3(0.3Mpa) 3(0.3Mpa)
Expansion tank capacity L 6 6 6 6
Preset pressure of Expansion tank bar 1(0.1Mpa) 1(0.1Mpa) 1(0.1Mpa) 1(0.1Mpa)
Pump lift M 5 5 5 5
Heating area reference 110 or lower 150 or lower 200 or lower 230 or lower
Temperature range of sanitary hot water 30-60 30-60 30-60 30-60
Applicated sanitary water pressure bar 0.2-6(0.02-0.6Mpa) 0.2-6(0.02-0.6Mpa) 0.2-6(0.02-0.6Mpa) 0.2-6(0.02-0.6Mpa)
Minimum start flow L/min 3 3 3 3
Minimum closed flow L/min 1.8 1.8 1.8 1.8
Exhaust type Forced & balanced  Forced & balanced  Forced & balanced  Forced & balanced 
Heating water circulation type Closed & forced Closed & forced Closed & forced Closed & forced
Ignition Type Impulsed automatic Impulsed automatic Impulsed automatic Impulsed automatic
Thermostat type(automatic) Proportional valve  Proportional valve  Proportional valve  Proportional valve 
Temp Display type LCD LCD LCD LCD
Working voltage V/Hz 220V/50Hz 220V/50Hz 220V/50Hz 220V/50Hz
Rated power W 110 110 110 110
Fuse A 3 3 3 3
Insulation grade I I I I
Pipe joint(gas input) inch G3/4 G3/4 G3/4 G3/4
Pipe jont(Heating pipes) inch G3/4 G3/4 G3/4 G3/4
Pipe jont(sanitary hot water) inch G1/2 G1/2 G1/2 G1/2
Flue Pipe joint(Air input/Exhaust duct) mm 60/90 60/90 60/100 60/100
Net weight/Gross weight kg 34/36 34/36 35/37 35/37
Packing size mm 830×460×375 830×460×375 830×460×375 830×460×375