Product Main

Specifications

Type 4C110-M5 4C120-M5 4C130C-M5 4C130E-M5 4C130P-M5 4C110-06 4C120-06 4C130C-06 4C130E-06 4C130P-06
Working medium filtrated compressed air
Action form inside pilot type
Bore size M5 G1/8''
Position and way No. 5/2 way 5/3 way 5/2 way 5/3 way
Max. operating pressure 1.2Mpa(170Psi)
Operating temperature range 23~140°F
Effective area 5.5m㎡ 5m㎡ 12m㎡ 9m㎡
Working pressure 0.15~0.8Mpa
Power consumption AC:2.5VA  DC:2.5W
Highest acting frequency 5time/sec 3time/sec 5time/sec 3time/sec
Protect degree IP65(DIN40050)
Electrical entry teminal type ordirecting outgoing line
Temperature classification  B
Voltage range ˉ15% ~+10%
Excitation time less than 0.05sec

Type 4C210-06 4C220-06 4C230-06 4C230E-06 4V230P-06 4C210-08 4C220-08 4C230C-08 4C230E-08 4C230P-08
Working medium filtrated compressed air
Action form inside pilot type
Bore size air in=air out=exhaust=G1/8 air in=air out=G1/4  exhaust=G1/8
Position and way No. 5/2 way 5/3 way 5/2 way 5/3 way
Max. operating pressure 1.2Mpa(12bar)
Operating temperature range -5 to 60 C(23~140°F)
Effective area 14mm2(Cv=0.78) 12mm2(Cv=0.67) 16mm2(Cv=0.89) 12mm2(Cv=0.67)
Working pressure 0.15~0.8Mpa
Power consumption AC:3.5VA  DC:2.5W
Highest acting frequency 5time/sec 3time/sec 5time/sec 3time/sec
Protect degree IP65(DIN40050)
Electrical entry teminal type ordirecting outgoing line
Temperature classification  B
Voltage range ˉ15% ~+10%
Excitation time less than 0.04sec

Type 4C310-08 4C320-08 4C330C-08 4C330E-08 4C330P-08 4C310-10 4C320-10 4C330C-10 4C330E-10 4C330P-10
Working medium filtrated compressed air
Action form inside pilot type
Bore size air in=air out=exhaust=G1/4 air in=air out=G3/8  exhaust=G1/4
Position and way No. 5/2 way 5/3 way 5/2 way 5/3 way
Max. operating pressure 1.2Mpa(12bar)
Operating temperature range -5 to 60 C(23~140°F)
Effective area 25mm 18mm 30mm 18mm
Working pressure 0.15~0.8Mpa
Power consumption AC:3.5VA  DC:2.5W
Highest acting frequency 4time/sec 3time/sec 4time/sec 3time/sec
Protect degree IP65(DIN40050)
Electrical entry teminal type ordirecting outgoing line
Temperature classification  B
Voltage range ˉ15% ~+10%
Excitation time less than 0.05sec

Type 4C410-15 4C420-15 4C430C-15 4C430E-15 4C430P-15
Working medium filtrated compressed air
Action form inside pilot type
Bore size air in=air out=exhaust=G1/2
Position and way No. 5/2 way 5/3 way
Max. operating pressure 1.2Mpa(12bar)
Operating temperature range -5 to 60 C(23~140°F)
Effective area 50mm2 30mm2
Working pressure 0.15~0.8Mpa
Power consumption AC:3.5VA  DC:2.5W
Highest acting frequency 3time/sec
Protect degree IP65(DIN40050)
Electrical entry teminal type ordirecting outgoing line
Temperature classification  B
Voltage range ˉ15% ~+10%
Excitation time less than 0.06sec