Humidity-sensitive  capacitor      Model:   MC02
High  quality  and  precision!
 
Produced  using  unique  semiconductor  technology,   so  the  HC02  can  be  utilized  in  most  occasions.
 
Features:  
Excellent  linearity,   low  power  consumption,   wide  measurement  range,   quick  response,   anti-pollution,   high  stability,   dehumidifys  quickly  after  long-term  saturation, high  performance-price  ratio.
 
Technical  Specification:
Operating  range:                                         0-100%RH          -40~200Celsius
Power  supply:                                             10V  AC  (Max)
Nominal  capacitance:                                 200+-10pF(25Celsius,   60%RH)
Sensitivity  average:                                     0. 5pF/%RH
Humidity  effects:                                           +1Celsius,   +0. 025pF
Power  consumption  factor:                           < 0. 01
Return  difference  of  humidity  hysteresis:     < 1%RH
Linear  error:                                                       < +-2%RH
Response  time:                                               < 5s
Operating  frequency:                                     5k--100kHz
Recovering  time  after  150  hours  dew  condensation:     < 10s
Stability:                                                                           < 1%RH/Year
Dimensions:                                                               with  case  6. 5*10*3mm,   without  case  5*7*0. 6mm