Product Main

Specifications

Introduce
Main technical data
Specification  :  SR868C8  
Appearance  of  controller:  120mm×120mm×18mm   
Power  supply   :     AC230V±10%
Power  consumption :    <  3W  
Accuracy of  temperature measuring : ±2oC                                       
Range  of  collector   temperature  measuring   :  -10~220oC 
Range  of  tank  temperature  measuring      :    0~110oC
Suitable  power  of  pump :  three  pumps,≤  600W
Suitable  power  of   electrical  heater   :     power≤  1500W
Inputs :
1  x  Pt1000  sensor  (≤500oC)  for  collector  (silicon  cable≤280oC), 
2  x  NTC10K,  B3950  sensor (≤  135oC)   for  tank,  (PVC  cable  ≤105oC), 
Outputs  :
3  relays,  for  circulation  pumps   or  3-way  electromagnetic  valve
1  relay  for  electrical  heater   
Ambient  temperature :                -10~50  oC    
Water  proof  grade:                      IP40   
 
Main functions
1.Main  menu  DT  O  &  DT  F  Temperature  difference  function
2.Main  menu-THET  timing  heating
3.TEMP  Temperature  main  menu
4.EM  Emergency  collector  temperature
(emergency  switch-off  temperature  of  collector)
5.CMX  Maximum  limited  collector  temperature  (collector  cooling  function)
6.CMN  low  temperature  protection  of  collector
7.CFR  frost  protection  of  collector
8.SMX  Maximum  temperature  of  tank
9.REC  Tank  re-cooling  function
10.Celsius  and  Fahrenheit  temperature  transferring
11.FUN  Auxiliary  function
12.DVWG  Anti-Legionella  function
13.CIRC  Temperature  controlled  hot  water  circulation  pump
14.nMIN  Solar  circulation  pump  speed  adjusting  (RPM  speed  controlling)(Only  available  on  SR868C8Q)
15.OHQM  Thermal  energy  measuring  (Only  available  on  SR868C8Q)
16.INTV  Pump  interval  function      (Only  available  on  SR868C8Q)
17.BYPR  High  temperature  by-pass  function
(tank  temperature  automatically  adjusting)
18.  HND  Manual  mode
19.PASS  Password  setting
20.LOAD  Recovery  to  factory  setting
21.ON/OFF  button
22.Holiday  function
23.Manual  heating
24.Temperature  query  function
25.Memory  Protection
26.Anti-dry  heating  Protection
27.Screen  protection