Product Main

Specifications

2  Electrical Characteristics

3.1 Dielectric Antenna
                     Form 1

No.

Item

Specifications

Post Environmental Tolerance

1

Frequency(MHz)

870~960MHz/1710~1990 MHz

±3 MHz

2

V.S.W.R(in BW )

≤1.6︰1

3

Gain(Zenith)

3.5 dB

±0.5 dB

4

Polarization

Vertical

5

Impedance

50 Ω


3.2 Mechanical

Form 2

No.

Item

Specification

1

Cable

2

Connector

SMA-JW

3

Plastic Housing

Black

4

Size

Φ9.2×51mm



4  Reliability
Condition:Temperature: 40±5℃
       Load: DC=5V±0.5 V
       Quantity: 2000pcs
       Sustained Time: 480h

5  Environmental Specifications
Condition:Post Environmental Tolerance (Refer to the form 1)
      Temperature range 25±3℃
      Relative Humidity range 55~75%RH
      Operating Temperature range -40℃~+85℃
      Storage Temperature range -40℃~+100℃
5.1 Moisture Proof
   The device should satisfy the electrical characteristics specified in form 1 after exposed to the temperature 40±2℃and the relative humidity 90~95% RH for 96 hours and 1~2 hours recovery time under normal condition.
5.2 Vibration Resist
   The device should satisfy the electrical characteristics specified in form 1 after applied to the vibration of 10 to 55Hz with amplitude of 1.5mm for 2 hours each in X , Y and Z directions.
5.3 Drop Shock
   The device should satisfy the electrical characteristics specified in form 1 after dropping onto the hard wooden board from the height of 30cm for 3 times each facet of the 3 dimensions of the device.
5.4 High Temperature Endurance
   The device should satisfy the electrical characteristics specified in form 1 after exposed to temperature 80±5℃for 24±2 hours and 1~2 hours recovery time under normal temperature.
5.5 Low Temperature Endurance
   The device should also satisfy the electrical characteristics specified in form 1 after exposed to the temperature -40℃±5℃for 24±2 hours and to 2 hours recovery time under normal temperature.
5.6 Temperature Cycle Test
   The device should also satisfy the electrical characteristics specified in form 1 after exposed to the low temperature -25℃ and high temperature +85℃ for 30±2 min each by 5 cycles and 1 to 2 hours recovery time under normal temperature.