Pure sine wave inverter
Input wave: pure sine
Nominal voltage: 120V/220V
Low voltage trip: 90V±4% 184V/154V ± 4%
Low voltage re engage: 100V±4% 194V/164V± 4%
High voltage trip: 140V±4% 253v± 4%
High voltage re engage: 135V±4% 243v ± 4%
Max input AC voltage: 150 VAC 270VAC
Norninal input frequency: 50 Hz OR 60 Hz(Auto Detect)
Low frequency trip: 47 Hz for 50 Hz, 57Hz for 60Hz
High frequency trip: 55 Hz for 50 Hz, 65Hz for 60Hz
Output wave form: (bypass mode) same as input.
Over load protection: Circuit breaker
Short circuit protecion: circuit breaker
Transfer switch rating: 30Amp or 40 amp
Efficiency online transfer mode: 95% +
Line transfer time: 10ms typical
Bypass without battery connected: Yes
Max bypass current: 30 amp or 40 amp
Bypass over current: 35 amp or 45 amp alarm
Output continuos power watts: 2000w
Output continuos power VA: 2000
Power factor: 09-1. 0
Output frequencey: 50 Hz ± 0. 3 HZ or 60 hz± 0. 3 HZ
Norninal effeciency: 88%
Surge rating: 6000W
Inverter specification:
Nonimal input voltage: 12V/24V/48V
Minimum start Voltage: 10V/20V/40V
Low battery alarm; 10. 5V/21V/42V
Low battery trip: 10V/20V/40V
High voltage alarm: 16V/32V/64V
Power saver: Below 25 watt when enabled
Power saver: same switched on/off on remote
Charger specification:
Input voltage range: 95-127VAC, 194-243VAC / 164-243VAC(W)
Output Voltage: Dependent on battery type
Battery Initial voltage for start up: 0-15. 7V for 12V ( *2 for 24V; *4 for 48V)
Over charge protection shut down: 15. 7V for 12V ( *2 for 24V; *4 for 48V)
Charge curves: (4 stage constant current) battery type: 4 Step digital controlled progressive charge.