switching power supply :
|
|||||||||||
Model Specification |
T-60A
|
T-60B
|
T-60C
|
||||||||
CH1
|
CH2
|
CH3
|
CH1
|
CH2
|
CH3
|
CH1
|
CH2
|
CH3
|
|||
DC output voltage |
5V
|
12V
|
-5V
|
5V
|
12V
|
-12V
|
5V
|
15V
|
-15V
|
||
Output voltage errorNote2 |
± 2% |
± 6%
|
± 6%
|
± 2% |
± 6%
|
± 6%
|
± 2% |
± 6%
|
± 6%
|
||
Rated output current |
5A |
2. 5A
|
0. 5A
|
5A |
2. 5A
|
0. 5A
|
5A |
2. 5A
|
0. 5A
|
||
Output current rage |
0. 5-7A |
0. 2-3. 5A
|
0-0. 1A
|
0. 5-7A |
0. 2-3. 5A
|
0-0. 1A
|
0. 5-7A |
0. 2-3. 5A
|
0-0. 1A
|
||
Wave and noise(Note 3 |
100mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
||
Inlet stability(Note 4 |
± 0. 5%
|
± 1%
|
± 0. 5%
|
± 0. 5%
|
± 1%
|
± 0. 5%
|
± 0. 5%
|
± 1%
|
± 0. 5%
|
||
Load stablity (Note 5 |
± 1%
|
± 4%
|
± 1%
|
± 1%
|
± 4%
|
± 1%
|
± 1%
|
± 4%
|
± 1%
|
||
DC output power |
57. 5W
|
61W
|
62. 5W
|
||||||||
Efficiency |
72%
|
72%
|
72%
|
||||||||
Adjustable range for DC voltage |
CH1; +10, -5%
|
CH1: +10, -5%
|
CH1: +10, -5%
|
||||||||
AC input voltage range | 85-264VAC 47-63Hz120-370VDC | ||||||||||
Input current | 2A/115V 1A/230A | ||||||||||
AC INnrush current |
Cold-start current 30A/115V 60A/230V |
||||||||||
Leakage current | < 1mA/240VAC | ||||||||||
Overload proctection | 105%-150%Type: Foldback: current limiting reset: auto recovery | ||||||||||
Over-voltage protection | CH1: 5. 75-6. 75V | ||||||||||
High-temperature protection | |||||||||||
Temperature coefficient | ± 0. 03%/0-50ON+5V | ||||||||||
Setup rise hold up time | 800ms, 50ms, 10ms/115VAC 300ms. 50ms, 80ms/230VAC | ||||||||||
Vibration | 10-500Hz, 2G 10min, /1cycle, Period for60min, Each axes | ||||||||||
Withstand voltage | Input and output internal1. 5KVAC, Input and enclosure1. 5KVAC, Output and enclosure0. 5KVAC | ||||||||||
Isolation resistance | Input and output internal: Input and enclosure, Output and enclosure500VDC/100MΩ | ||||||||||
Working temperature and humidity | -10~+60Refer to output derating curve, 20%~90%RH | ||||||||||
Store temperature and humidity | -20~+85. 10%~95%RH | ||||||||||
Overall dimension | 159× 97× 38mm | ||||||||||
Weight | 0. 56Kgs | ||||||||||
Safety standards | UL 1012 TUV EN60950(IEC950, UL1950) | ||||||||||
EMC standards | CISPR22(EN55022), class B, IEC801-2, -3, -4, IEC555-2 Verification | ||||||||||
Note 1. The testing condition for the paramenter above is : 230VAC input, rated load, 2570% RH. Humidity. 2. Error. include the setting error, line stability and load stability. (Note: 5). 3. Wave test: adopting " A12" double wire for 20MHz, and 0. 1UF& 47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: the load is from 0% to 100%. 6. Total output canbe maximum Current, total load can not exceed the maximum output power. 7. C23must be knocked down. |