switching power supply :

 

  Low price and high reliability
105 output capacitor
AC input power suitable for the world
Hight efficiency and low operation temperature
Soft-start current can reduce the AC input impact effecticly
With Short-circuit and owwerload protection
Compact size, light weight
100% full-load burning test
Installed with EMI filter, minimum wave
Model
Specification
T-60A
T-60B
T-60C
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
DC output voltage
5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
Output voltage errorNote2

± 2%

± 6%
± 6%

± 2%

± 6%
± 6%

± 2%

± 6%
± 6%
Rated output current

5A

2. 5A
0. 5A

5A

2. 5A
0. 5A

5A

2. 5A
0. 5A
Output current rage

0. 5-7A

0. 2-3. 5A
0-0. 1A

0. 5-7A

0. 2-3. 5A
0-0. 1A

0. 5-7A

0. 2-3. 5A
0-0. 1A
Wave and noise(Note 3
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
Inlet stability(Note 4
± 0. 5%
± 1%
± 0. 5%
± 0. 5%
± 1%
± 0. 5%
± 0. 5%
± 1%
± 0. 5%
Load stablity (Note 5
± 1%
± 4%
± 1%
± 1%
± 4%
± 1%
± 1%
± 4%
± 1%
DC output power
57. 5W
61W
62. 5W
Efficiency
72%
72%
72%
Adjustable range for DC voltage
CH1; +10, -5%
CH1: +10, -5%
CH1: +10, -5%
AC input voltage range 85-264VAC 47-63Hz120-370VDC
Input current 2A/115V 1A/230A
AC INnrush current

Cold-start current 30A/115V 60A/230V

Leakage current < 1mA/240VAC
Overload proctection 105%-150%Type: Foldback: current limiting reset: auto recovery
Over-voltage protection CH1: 5. 75-6. 75V
High-temperature protection  
Temperature coefficient ± 0. 03%/0-50ON+5V
Setup rise hold up time 800ms, 50ms, 10ms/115VAC 300ms. 50ms, 80ms/230VAC
Vibration 10-500Hz, 2G 10min, /1cycle, Period for60min, Each axes
Withstand voltage Input and output internal1. 5KVAC, Input and enclosure1. 5KVAC, Output and enclosure0. 5KVAC
Isolation resistance Input and output internal: Input and enclosure, Output and enclosure500VDC/100MΩ
Working temperature and humidity -10~+60Refer to output derating curve, 20%~90%RH
Store temperature and humidity -20~+85. 10%~95%RH
Overall dimension 159× 97× 38mm
Weight 0. 56Kgs
Safety standards UL 1012 TUV EN60950(IEC950, UL1950)
EMC standards CISPR22(EN55022), class B, IEC801-2, -3, -4, IEC555-2 Verification
Note
1. The testing condition for the paramenter above is : 230VAC input, rated load, 2570% RH. Humidity.
2. Error. include the setting error, line stability and load stability. (Note: 5).
3. Wave test: adopting " A12" double wire for 20MHz, and 0. 1UF& 47UF capacitor short-circuit for interrupting.
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.
5. Load stability test: the load is from 0% to 100%.
6. Total output canbe maximum Current, total load can not exceed the maximum output power.
7. C23must be knocked down.