Switching power supply :
Model | S-50-5S-50-12S-50-15S-50-24||||
Specification | ||||
DC output voltage |
5V
|
12V
|
15V
|
24V
|
Output voltage errorNote2 |
±2%
|
±1%
|
±1%
|
±1%
|
Rated output current |
10A
|
4.2A
|
3.4A
|
2.1A
|
Output current rage |
0-10A
|
0-4.2A
|
0-3.4A
|
0-2.1A
|
Wave and noise(Note 3 |
75mVp-p
|
100mVp-p
|
100mVp-p
|
100mVp-p
|
Inlet stability(Note 4 |
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
Load stablity (Note 5 |
±1%
|
±0.5%
|
±0.5%
|
±0.5%
|
DC output power |
50W
|
50.4W
|
51W
|
50.4W
|
Efficiency |
75%
|
78%
|
78%
|
82%
|
Adjustable range for DC voltage |
+10,-5%
|
±10%
|
±10%
|
±10%
|
AC input voltage range | AC100~240V 47~63Hz;240~370VDC | |||
Input current | 1.3A/115V 0.65A/230V | |||
AC INnrush current |
Cold-start current 18A/115V 36A/230V |
|||
Leakage current | <0.5mA/240VAC | |||
Overload proctection | 105%~150% Tpye:Foldback current limiting Reset: auto recovery | |||
Over-voltage protection | ||||
High-temperature protection | ||||
Temperature coefficient | ±0.03%/(0~50%) | |||
Setup rise hold up time |
200s,100ms,30ms |
|||
Vibration | 10~500Hz,2G 10min,/1cycle,Period for 60min,each axes | |||
Withstand voltage | Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC | |||
Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ | |||
Working temperature and humidity | -10~+60Refer to output derating curve,20%~90%RH | |||
Store temperature and humidity | -20~+85,10%~95%RH | |||
Overall dimension | 100×58×32mm | |||
Weight | 0.5Kgs | |||
Safety standards | Meet UL1012 requirement(Not qpply for the mark) | |||
EMC standards | ||||
Note 1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity. 2.Error.Include the setting error,line stability and load stability.(Note:5). 3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100%. |