Product Main

Specifications

Switching power supply :

 

S-50-5S-50-12S-50-15S-50-24
Model
Specification
DC output voltage
5V
12V
15V
24V
Output voltage errorNote2
±2%
±1%
±1%
±1%
Rated output current
10A
4.2A
3.4A
2.1A
Output current rage
0-10A
0-4.2A
0-3.4A
0-2.1A
Wave and noise(Note 3
75mVp-p
100mVp-p
100mVp-p
100mVp-p
Inlet stability(Note 4
±0.5%
±0.5%
±0.5%
±0.5%
Load stablity (Note 5
±1%
±0.5%
±0.5%
±0.5%
DC output power
50W
50.4W
51W
50.4W
Efficiency
75%
78%
78%
82%
Adjustable range for DC voltage
+10,-5%
±10%
±10%
±10%
AC input voltage range AC100~240V 47~63Hz;240~370VDC
Input current 1.3A/115V 0.65A/230V
AC INnrush current

Cold-start current 18A/115V 36A/230V

Leakage current <0.5mA/240VAC
Overload proctection 105%~150% Tpye:Foldback current limiting Reset: auto recovery
Over-voltage protection  
High-temperature protection  
Temperature coefficient ±0.03%/(0~50%)
Setup rise hold up time

200s,100ms,30ms

Vibration 10~500Hz,2G 10min,/1cycle,Period for 60min,each axes
Withstand voltage Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC
Isolation resistance Input and output internal:Input and enclosure,Output and enclosure500VDC/100MΩ
Working temperature and humidity -10~+60Refer to output derating curve,20%~90%RH
Store temperature and humidity -20~+85,10%~95%RH
Overall dimension 100×58×32mm
Weight 0.5Kgs
Safety standards Meet UL1012 requirement(Not qpply for the mark)
EMC standards  
Note 1.The testing condition for the paramenter above is :230VAC input,rated load,2570% RH.Humidity. 2.Error.Include the setting error,line stability and load stability.(Note:5). 3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100%.