SWITCH POWER SUPPLY
| Model | MS-15-5 MS-15-12 MS-15-24|||
| Specification | |||
| DC output voltage |
5V
|
12V
|
24V
|
| Output voltage errorNote2 |
±2%
|
A±1%
|
±1%
|
| Rated output current |
3A
|
1.3A
|
0.7A
|
| Output current rage |
0-3A
|
0-1.3A
|
0-0.7A
|
| Wave and noise(Note 3 |
50mVp-p
|
50mVp-p
|
100mVp-p
|
| Inlet stability(Note 4 |
±0.5%
|
±0.5%
|
±0.5%
|
| Load stablity (Note 5 |
±1%
|
±0.5%
|
±0.5%
|
| DC output power |
15W
|
15.6W
|
16.8W
|
| Efficiency |
65%
|
68%
|
72%
|
| Adjustable range for DC voltage |
10, -5%
|
10%
|
±10%
|
| AC input voltage range | AC100~240VAC 47-63Hz; 240~370VDC | ||
| Input current | 0. 5A/115V 0. 25A/230V | ||
| AC INnrush current |
Cold-start current 15A/115V 30A/230V
|
||
| Leakage current | < 0. 5mA/240VAC | ||
| Overload proctection | 105%~150% Tpye: Foldback current limiting Reset: auto recovery | ||
| Over-voltage protection | |||
| High-temperature protection | |||
| Temperature coefficient | ±0. 02%/(0~50%) | ||
| Setup rise hold up time |
200s, 100ms, 30ms
|
||
| Vibration | 10~500Hz, 2G 10min, /1cycle, Period for 60min, each axes | ||
| Withstand voltage | Input and output internal1. 5KVAC, Input and enclosure1. 5KVAC, Output and enclosure0. 5KVAC | ||
| Isolation resistance | Input and output internal: Input and enclosure, Output and enclosure500VDC/100MΩ | ||
| Working temperature and humidity | -10~+60Refer to output derating curve, 20%~90%RH | ||
| Store temperature and humidity | -20~+85, 10%~95%RH | ||
| Overall dimension | 120×46×32mm | ||
| Weight | 0. 3Kgs | ||
| Safety standards | Meet UL1012 requirement(Not qpply for the mark) | ||
| EMC standards | Meet FCC PART15 J Conduction class B | ||
|
Note 1. The testing condition for the paramenter above is : 230VAC input, rated load, 2570% RH. Humidity. 2. Error. include the setting error, line stability and load stability. (Note: 5). 3. Wave test: adopting "A12"double wire for 20MHz, and 0. 1UF& 47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: the load is from 0% to 100%. |
|||