| Features: Universal AC input/Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 Isolation class LED indicator for power on 100% full load burn-in test | ||||
| MODEL | DR-30-5 | DR-30-12 | DR-30-15 | DR-30-24 |
| DC VOLTAGE | 5V | 12V | 15V | 24V |
| RATED CURRENT | 3A | 2A | 2A | 1.5A |
| CURRENT RANGE | 0 ~ 3A | 0 ~ 2A | 0 ~2A | 0 ~ 1.5A |
| RATED POWER | 15W | 24W | 30W | 36W |
| RIPPLE & NOISE (max.) | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
| VOLTAGE ADJ. RANGE | 4.75 ~ 5.5V | 10.8 ~ 13.2V | 13.5 ~ 16.5V | 21.6 ~ 26.4V |
| VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | ±1.0% |
| LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| SETUP, RISE TIME | 100ms, 30ms/230VAC 100ms, 30ms/115VAC at full load | |||
| HOLD TIME(Typ.) | 100ms/230VAC 30ms/115VAC at full load | |||
| VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 370VDC | |||
| FREQUENCY RANGE | 47 ~ 63Hz | |||
| EFFICIENCY (Typ.) | 74% | 81% | 82% | 83% |
| AC CURRENT | 0.88A/115VAC 0.48A/230VAC | |||
| INRUSH CURRENT(max.) | COLD START 15A/115VAC 30A/230VAC | |||
| OVERLOAD | 105 ~ 160% rated output power | |||
| Protection type : Constant current limiting,recovers automatically after fault condition is removed | ||||
| OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V |
| Protection type : Shut down o/p voltage,re-power on to recover | ||||
| WORKING TEMP. | -20 ~ +60oC | |||
| WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
| STORAGE TEMP., HUMIDITY | -20 ~ +85oC , 10 ~ 95% RH | |||
| TEMP. COEFFICIENT | ±0.03%/oC (0 ~ 50oC) | |||
| VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||
| SAFETY STANDARDS | Design refer to UL60950-1,TUV EN60950-1,EN50178 | |||
| WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
| ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||
| EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | |||
| HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | |||
| EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, Light industry level, criteria A | |||
| MTBF | 441.5K hrs min. MIL-HDBK-217F (25oC) | |||
| DIMENSION | 78*93*56mm (L*W*H) | |||
| PACKING | 0.27Kg; 48pcs/14Kg/1.02CUFT | |||