APPLICATION:
 
Mainly applied in the meter testing centers of electricity utilities, authoritative energy measurement labs, kWh meter manufacturer, authoritative centers for energy meter calibration, and electricity engineering companies.
 
FUNCTIONS:
 
·Measure voltage/current/frequency/phase/power factor/active power/reactive power/appearance power of 3-phase 3-wire or 3-phase 4-wire.
·Measure harmonic content and waveform distortion from 2nd to 63rd.
·Display wave shape for each phase at real time.
·Able to test the single phase and three phase meter for both active and reactive.
·Display vector diagram in order to facilitate wire-checking; with auto connection recognition software; able to recognize various connection circuit of 3-phase 3-wire or 3-phase 4-wire either through CT or direct testing; report the result of connection recognition and the coefficient of deviation.
 
FEATURES:
 
·6.4',640×480 dot, 16 color LCD, English interface.
·Lithium battery, continuous working time over 5 hours.
·Able to test two meters at the same time or test active and reactive energy of one meter;
·Clamp-on testing: able to be equipped with four sets of clamps at the same time: 5A, 100A, 500A, 1000A; also able to test directly with high accuracy via accessories.
·Able to measure CT ratio error/angle error directly.
·Optical port: able to read the data of energy meter complying to DL645 protocol.
·Input jack of bar-code reader; Software automatic calibration.
·USB and PCMCIA interfaces, 10,000 meters testing result memory, and able to be transferred to CLOU administration software.
·Portable and light type.
 
TECHNICAL SPECIFICATION:
 
ACTIVE POWER MEASUREMENT:
·Direct Measurement:
   0.05%RD (voltage 30V~456V, current 0.1A~12A, PF≥0.5)
   0.1%RD (voltage 30V~456V, current 0.05A~0.1A, PF=1)
   0.05%RD (voltage 30V~456V, current 0.02A~2.4A, PF≥0.5)
   0.1%RD (voltage 30V~456V, current 0.01A~0.02A, PF=1)
·Clamp-on Measurement:
   0.2%RD (voltage 30V~456V, current 10%In~120%In, PF≥0.5)
   0.3%RD (voltage 30V~456V, current 5%In~10%In, PF≥0.5)
   0.5%RD (voltage 30V~456V, current 1%In~5%In, PF=1)
 
CURRENT MEASUREMENT:
·Direct Measurement: 
    0.05%RD(0.1A~12A),0.05°
    0.1%RD(0.05A~0.1A),0.1°
    0.05%RD(0.02A~2.4A),0.05°
    0.1%RD(0.01A~0.02A),0.1°
·Clamp-on Measurement: 
    0.2%RD(10%In~120%In),0.2°
    0.3%RD(5%In~10%In),0.3°
    0.5%RD(1%In~5%In),0.5°
 
ACTIVE ENERGY MEASUREMENT:
·Direct Measurement: 
   0.05%RD (voltage 30V~456V, current 0.1A~12A, PF≥0.5)
   0.1%RD (voltage 30V~456V, current 0.05A~0.1A, PF=1)
   0.05%RD (voltage 30V~456V, current 0.02A~2.4A, PF≥0.5)
   0.1%RD (voltage 30V~456V, current 0.01A~0.02A, PF=1)
·Clamp-on Measurement:
   0.2%RD (voltage 30V~456V, current 10%In~120%In, PF≥0.5)
   0.3%RD (voltage 30V~456V, current 5%In~10%In, PF≥0.5)
   0.5%RD (voltage 30V~456V, current 1%In~5%In, PF=1)
 
 REACTIVE ENERGY MEASUREMENT:
·Direct Measurement: 
   0.1%RD (voltage 30V~456V, current 0.1A~12A, PF≥0.5)
   0.2%RD (voltage 30V~456V, current 0.05A~0.1A, PF=1)
   0.1%RD (voltage 30V~456V, current 0.02A~2.4A, PF≥0.5)
   0.2%RD (voltage 30V~456V, current 0.01A~0.02A, PF=1)
·Clamp-on Measurement:
   0.5%RD (voltage 30V~456V, current 10%In~120%In, PF≥0.5)
   0.75%RD (voltage 30V~456V, current 5%In~10%In, PF≥0.5)
   1.0%RD (voltage 30V~456V, current 1%In~5%In, PF=1)
 
REACTIVE POWER MEASUREMENT:
·Direct Measurement:
    0.1%RD(voltage 30V~456V, current 0.1A~12A, PF≥0.5)
    0.2%RD(voltage 30V~456V, current 0.05A~0.1A, PF=1)
    0.1%RD(voltage 30V~456V, current 0.02A~2.4A, PF≥0.5)
    0.2%RD(voltage 30V~456V, current 0.01A~0.02A, PF=1)
·Clamp-on Measurement:
    0.5%RD (voltage 30V~456V, current 10%In~120%In, PF≥0.5)
    0.75%RD (voltage 30V~456V, current 5%In~10%In, PF≥0.5)
    1.0%RD (voltage 30V~456V, current 1%In~5%In, PF=1)
 
 PHASE MEASUREMENT: 
·Range: 0°~  359.99°
·Direct Measurement: 
    0.05°(voltage 30V~456V, current 0.1A~12A)
    0.1°  (voltage 30V~456V, current 0.05A~0.1A)  
    0.05°(voltage 30V~456V, current 0.02A~2.4A)
    0.1° (voltage 30V~456V, current 0.01A~0.02A)
·Clamp-on Measurement:
    0.2°(voltage 30V~456V, current 10%In~120%In)
    0.3° (voltage 30V~456V, current 5%In~10%In)
0.5°(voltage 30V~456V, current 1%In~5%In)
 
PULSE OUTPUT:
·(Constant r/kwh)range: 1~9999999999
·Highest pulse frequency: 50kHz
 
PULSE INPUT:
·MUT( meter under test) constant (r/kWh)range:
   1~9999999999
·Testing pulse number range (can be set):
   1~(65535×65535)
·Highest pulse frequency: 50kHz
 
 RECHARGEABLE BATTERY:
·Range: AC85~AC265V, 20W
 
 WORKING CONDITIONS: 
·Temperature: -20℃~55℃     
·Relative humidity:≤85%
 
 DIMENSION & WEIGHT:
·Dimension: 257mm×176mm×67mm
·Weight: <3KG
 
 VOLTAGE MEASUREMENT:
·Range: 0~456V   
·Accuracy: 0.05%RD(30V~456V)
 
 FREQUENCY MEASUREMENT:     
·Range: 45Hz~65Hz
·Accuracy: 0.01Hz   Resolution: 0.001Hz
·Power factor measurement: Range: -1.0~0~+1.0
·Direct measurement: 0.0005 (voltage 30V~456V, current 0.1A~12A)
·Clamp on measurement: 0.002 (voltage 30V~456V, current 10%In~120%In)