1) Accuracy level: Level 0.1
2) Output voltage: 220V
Regulating scope: 0-120% consecutively adjustable
Regulating fineness: Better than 0.01%
* Special voltage range can be setup according to user order.
3) Current range: 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 20A, 50A, 100A
Regulating scope: 0-120% consecutively adjustable
Regulating fineness: Better than 0.01%
4) Output power; (voltage loop) 100VA; (current loop) 150VA
5) Stability of output voltage, current and power: ≤0.05%/120S PF=1 (level O. 1type)
6) Wave distortion of output voltage and current: ≤0.5%
7) Symmetry of three phase: Better than 120o +0.3o
8) Frequency range: 45Hz 65Hz regulating fineness: 0.1 Hz
9) Phase shifting range: -180.0o 180.0 o regulating fineness: 0.01
10) Indicating instruments class
Voltmeter and ammeter accuracy: Level +0.3%
Phase meter accuracy: + 0.1o
Cymometer accuracy: +0.1Hz
11) Maximum meters for test: 3, 4
12) Power supply: 220+10%~50Hz (or user order)
13) Maximum power consumption: 300VA
14) Working environment: Temperature; 20+5 (5 50)
Relative humidity: ≤90%