Product Main

Specifications

RG-11/U Broadband Coax Cable
  • Lowest loss cable available, excellent for long runs between antenna and OTA receiver
  • 3.65 dB attenuation per 100' at 750 MHz
  • 14 AWG Bare Copper Covered Steel Conductor
  • Foam PE - Gas Injected Foam Polyethylene insulation
  • Dual Shield - 100% Bonded Al Foil - 67% Al Braid
  • Virgin PVC - Polyvinyl Chloride jacket (black)
Mechanical Characteristics

 

Minimum Breaking
Single Cable
82kgs
Dual Cable
166kgs
cohesive force between center conductor and Dielectric
> 20N/5mm
 
Electrical Characteristics :

 

Capacitance
50+/-3.0 nf/km
Impedance
75+/-3 ohm
Velocity
85%
Dielectric
Effectiveness
55Mhz
>=60db
300Mhz
>=70db
1000Mhz
>=70db
Return Loss
1~470Mhz
>=22db
100% Swept
470~1000Mhz
>=20db
 
1000~2200Mhz
>=18db
 
 
Attenuation Constant

 

attenuation
 
Frequency (Mhz)
Minimum (db/100ft.)
Maximum(db/100ft.)
5
0.39
1.25
55
0.96
3.15
83
1.18
3.87
187
1.75
5.74
211
1.90
6.23
250
2.05
6.72
300
2.25
7.38
350
2.42
7.94
400
2.60
8.53
450
2.75
9.02
500
2.90
9.51
550
3.04
9.97
600
3.18
10.43
750
3.65
11.97
865
3.98
13.05
1000
4.35
14.27