Sure LDG electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.
There are two basic components of Sure electromagnetic flow meter: 1)The Detector, which includes the flow tube, isolating liner and measuring electrodes, and 2) The Converter, which is the electronic device responsible for signal processing, flow calculation, display and output signals.
The materials of construction of the wetted parts (liner and electrodes) should be appropriate for the specifications on the intended type of service. Review of the compatibilities consistent with the specifications is recommended.
All SURE's electromagnetic flow meters are factory tested and calibrated. A calibration certificate is included in the shipment of each meter.
The integrative and split type electromagnetic flowmeter of our company can be divided into two classes, the explosion-proof structure with its ex-mark dmIIBT4 and the general structure.
|
Diameter (mm) |
10 |
15 |
20 |
25 |
32 |
40 |
50 |
65 |
|
Qmin (m 3 /h) |
0.08 |
0.34 |
0.34 |
0.53 |
0.87 |
1.35 |
2.1 |
3.5 |
|
Qmax (m 3 /h) |
2 |
8 |
8 |
12 |
20 |
32 |
49 |
84 |
|
Diameter (mm) |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
350 |
|
Qmin (m 3 /h) |
5.4 |
8.5 |
13 |
19 |
34 |
53 |
76 |
104 |
|
Qmax (m 3 /h) |
127 |
197 |
310 |
445 |
791 |
1236 |
1780 |
2423 |
|
Diameter (mm) |
400 |
450 |
500 |
550 |
600 |
700 |
800 |
900 |
|
Qmin (m 3 /h) |
136 |
191 |
212 |
263 |
305 |
415 |
543 |
760 |
|
Qmax (m 3 /h) |
3165 |
4294 |
4945 |
6322 |
7122 |
9693 |
12660 |
17634 |
Model Selection (See Table 1) Table 1. Model Selection Guidance
| Model Suffix Code | Description | |||||||||
| LDG- | ||||||||||
| Diameter | 10-2200mm | |||||||||
| combination | S | Integrated type | ||||||||
| L | Remote type | |||||||||
| Electrode Material | M | Stainless steel 316 | ||||||||
| T | Ti | |||||||||
| D | Ta | |||||||||
| H | Hastelloy alloy | |||||||||
| P | Pt | |||||||||
| N | Ni | |||||||||
| Signal Output | 0 | No output | ||||||||
| 1 | 4-20mA/1-5KHz | |||||||||
| Liner material | X | FEP | ||||||||
| F | PTFE | |||||||||
| Display Unit | 0 | No display unit | ||||||||
| 1 | Display unit | |||||||||
| Communication | 0 | No communication | ||||||||
| 1 | RS485 | |||||||||
| 2 | MODBUS | |||||||||
| Grounding Ring | 0 | No grounding ring | ||||||||
| 1 | Grounding ring | |||||||||
| Maximum Flow | (n) | Maximum flow (measuring range) m 3 /h | ||||||||