Product Main

Specifications

Temperature-Pressure-Flow Velocity Monitor System
KPV2000 Temperature-Pressure-Flow Velocity On-line Monitoring System has the characters of simple structure, easy to maintain. Because of the unique structure function, the working life is improved a lot, and maintenance interval is also prolonged.
KPV2000 Temperature-Pressure-Flow Velocity On-line Monitoring System is suitable for various working conditions, such as high dust, high temperature and high humidity condition etc.
Features
  • Proof against high temperature (the flue gas temperature of 1100℃ can be analysed), non-corroding and could be used in poor working environment
  • Easy to dismount and operate
  • High measuring precision and low cost
  • Automatically purging system prevents the pitot tube from being blocked in moist and dust laden flue gas
  • Long life working time
  • Easy to maintain
Application
  • Power system
  • Thermal power plants
  • Industrial boilers
  • Heating boilers
  • Organic chemical enterprises
  • Waste incineration stations
Technical specifications
Flow velocity

Monitoring method
pressure difference method
Type
KPV-2000
Measuring range
0~30m/s
Relative error
≤±10%
Precision
≤5%
Resolution
0. 1m/s
Response time
≤20s
Power consumption
< 0. 04KVA
Outputs signal
4-20mA

Temperature

Monitoring method
platinum resistor method
Type
KPV-2000
Measuring range
0~300℃ (adjustable for higher temperature)
Indicating value error
≤±3℃
Detection limit
0. 1℃
Precision
≤5%
Resolution
0. 1℃
Response time
≤20s
Power consumption
< 0. 04KVA
Outputs signal
4-20mA

Pressure

Monitoring method
direct measurement method by pressure sensor
Type
KPV-2000
Measuring range
-4KPa~4KPa
Power consumption
< 0. 04KVA
Outputs signal
4-20mA