1. Model: AK-200FC/C3
2. Electrochemistry type sensor(Japan)
3. Gas detected: carbon monoxide
4. Size: 100mm*35mm
5. Working voltage: AC220/AC110; 12VDC-20VDC
6. Additional Function: can work with solenoid valve or manipulator
7. Networking: wired networking(NO; NC)
8. Wireless networking mode: 315MHZ/433MHZ (2262 OR 1527)
9. Patent number: 200830104026.6
10.Options of gas density and alarm level:
EN (EN50291)
|
Density (PPM) |
50 |
100 |
300 |
400 |
|
Alarm time(Minutes) |
60-90 |
10-40 |
<3 |
Immediately |
CN (CNHINA)
|
Density (PPM) |
≥150 |
|
Alarm time (Seconds) |
5 |