Product Main

Specifications

High Pressure Gas Booster up to 35,000 PSI (241 Mpa)

Gas boosters are used to intensify a variety of gases including argon, helium, nitrogen, and hydrogen.  Used for virtually all known gases, high pressure gas boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Some common uses with a booster or booster system are to scavenge bottled gases once the pressure has fallen below operational requirements, pressure testing vessels, laser cutting, aircraft ground support equipment and injection molding. Gas Boosters works much the same as our high pressure liquid pumps in which a larger air drive piston is directly connected to a smaller pumping piston. The incoming air from the compressor drives the booster and also feeds the supply to the unit.

 







FEATURES & BENEFITS
  • Both pressure and volume of flow are easily and accurately controlled by a pressure regulator installed in the air supply line.
  • Can operate with almost any type of non-acid gas
  • High output capacity and outstanding performance provided at very low cost.
  • Designed for easy maintenance with minimum components and joints
  • High output capacities up to 35,000 PSI (210 Mpa)
  • Wide range of output capacities – less than 150 PSI (1 Mpa) air pressure is required to attain maximum rate of flow
  • Simple operating principle - a larger air-driven piston delivers pressure to a proportionally lesser diameter hydraulic piston, providing fluid flow at relatively higher pressures.
  • Complete flexibility – IVS boosters adapt to a wide variety of applications, from simple manual controls to fully automatic operation. Air motors are interchangeable for most models within each series.
  • Cycle automatically. When compressed air is first applied to the pump, it will cycle at its maximum speed producing maximum flow. The pump will then gradually start to cycle at a slower rate as the pressure in the receiver increases and stop automatically when the output pressure force and the air drive force is balanced to create a stall condition. At this point, the pump will maintain pressure without energy consumption, thus providing an economical source for hydraulic power.
 
TYPICAL APPLICATIONS

  • Extra force for small air clamps, roll tensioners, assembly machines and air presses.
  • Top off and maintain pressure in die cushions.
  • Release spring actuated brakes
  • Top off high pressure tires.
  • Increase marginal air pressure to valve actuators.
  • Increase maximum torque on small air tools.
  • Engine air starter systems.


ORDERING HIGH PRESSURE GAS BOOSTER

Gas Booster Model Max Pressure-in Max Pressure-out Gas Booster Air-in Connection Gas Booster Air-out Connection Output Pressure (Po) Volume /Stroke
(in)
Min Air Supply Pressure Gas Booster Max Output Pressure Gas Booster Max Output Ratio
IGB-15 2250 Psi 2250 Psi (1/4" NPT) (1/4" NPT) 15 Pa 7.05 3.5 bar(50psi) 155 bar(2250 psi) 20:01
IGB-30 4500 Psi 4500 Psi (1/4" NPT) (1/4" NPT) 30 Pa 3.1 7 bar(100 psi) 310 bar(4500 psi) 25:01:00
IGB-75 6000 Psi 11250 Psi (9/16"-18thd 1/4"H.P tube) (9/16"-18thd 1/4"H.P tube) 75 Pa 1.2 17 bar(250 psi) 775 bar(11,250 psi) 25:01:00
IGB-D30 6000 Psi 9000 Psi (1/4" NPT) (1/4" NPT) 60 Pa 3.1 13 bar(200 psi) 620 bar(9,000 psi) 25:01:00
IGB-D75 6000 Psi 20000 Psi (9/16"-18thd 1/4"H.P tube) (9/16"-18thd 1/4"H.P tube) 150 Pa 1.2 17 bar(250 psi) 1380 bar(20,000 psi) 25:01:00
IGBD-5 1500 Psi 1500 Psi (1/2" NPT) (1/2" NPT) 4.7 Pa+Ps 28.2 25 psi 1,500 psi 10:01
IGBD-15 5000 Psi 5000 Psi (1/4" NPT) (1/4" NPT) 15 Pa+Ps 14.1 3.5 bar(50 psi) 345 bar(5000 psi) 20:01
IGBD-30 6000 Psi 9000 Psi (1/4" NPT) (1/4" NPT) 30 Pa+Ps 6.3 7 bar(100 psi) 620 bar(9000 psi) 25:01:00
IGBD-75 6000 Psi 20000 Psi (9/16"-18 thd (1/4" H.P.Tube) (9/16"-18 thd (1/4" H.P.Tube) 75 Pa+Ps 2.4 17 bar(250 psi) 1380bar(20,000psi) 25:01:00
IGBD-D15 5000 Psi 5000 Psi (1/4" NPT) (1/4" NPT) 30 Pa+Ps 14.1 3.5 bar(50 psi) 345 bar(5000 psi) 20:01
IGBD-D30 6000 Psi 9000 Psi (1/4" NPT) (1/4" NPT) 60 Pa+Ps 6.3 14 bar(200 psi) 620 bar(9000 psi) 25:01:00
IGBD-D75 6000 Psi 25000 Psi (9/16"-18 thd (1/4" H.P.Tube) (9/16"-18 thd (1/4" H.P.Tube) 150 Pa+Ps 2.4 17 bar(250 psi) 1725bar (25,000psi) 25:01:00
IGBT-15/30 15 Pa 9000 Psi (1/4" NPT) (1/4" NPT) 30Pa+2Ps 7.05 3.5 bar(50 psi) 586 bar(8500 psi) 50:01:00
IGBT-D15/30 30 Pa 9000Psi (1/4" NPT)  (1/4"NPT) 60 Pa+2Ps 7.05 7 bar(100 psi) 621 bar(9,000 psi) 50:01:00
IGBT-15/75 3.5 Pa 20000 Psi (9/16"-18 thd (1/4" H.P.Tube) (9/16"-18 thd (1/4" H.P.Tube) 75 Pa+5Ps 7.05 3.5bar(50 psi) 896 bar(13,000 psi) 100:01:00
IGBT-30/75 20 Pa 20000 Psi (9/16"-18 thd (1/4" H.P.Tube) (9/16"-18 thd (1/4" H.P.Tube) 75 Pa+2.5Ps 3.1 7 bar(100 psi) 1103 bar(16,000psi) 60:01:00
IGBT-D15/75 7 Pa 25000 Psi (9/16"-18 thd (1/4" H.P.Tube (9/16"-18 thd (1/4" H.P.Tube) 150 Pa+5Ps 7.05 7 bar(100 psi) 1725bar(25,000psi) 100:01:00
IGBT-D30/75 40 Pa 25000 Psi (9/16"-18 thd (1/4" H.P.Tube (9/16"-18 thd (1/4" H.P.Tube) 150 Pa+2.5Ps 3.1 7 bar(100 psi) 1725bar(25,000psi) 60:01:00
IGB14AGT-125/315 82Pa 35000psi (3/4"-16 thd (3/8" H.P.Tube (3/4"-16 thd (3/8" H.P.Tube) 315Pa + 2.5Ps 4.44 6.9bar(100psi) 2415bar(35000psi) 40:01:00
Note: Ps=gas supply pressure; Pa=air driving pressure, Po=gas output pressure
Max. Pa is 150 psi