Temperature classification is B. High mechanical property, stable dielectric property after immersing in water. It’s a kind of current fabric laminate with excellent and comprehensive property. Used as slot and wedge of motors, the insulating structural parts for electric machine and apparatus equipment.
Technical requirements are shown in table 1, 2, 3 and 4.
Table 1: Nominal thickness and tolerance
|
Nominal thickness
mm |
Tolerance
mm |
|
Nominal thickness
mm |
Tolerance
mm |
|
0.4 |
±0.10 |
5.5 |
— | |
|
0.5 |
±0.12 |
6.0 |
±0.60 | |
|
0.6 |
±0.13 |
6.5 |
— | |
|
0.8 |
±0.16 |
8.0 |
±0.72 | |
|
1.0 |
±0.18 |
10.0 |
±0.82 | |
|
1.2 |
±0.20 |
12.0 |
±0.94 | |
|
1.5 |
— |
14.0 |
±1.02 | |
|
1.6 |
±0.24 |
16.0 |
±1.12 | |
|
1.8 |
— |
20.0 |
±1.30 | |
|
2.0 |
±0.28 |
25.0 |
±1.50 | |
|
2.5 |
±0.33 |
30.0 |
±1.70 | |
|
3.0 |
±0.37 |
35.0 |
±1.95 | |
|
3.5 |
— |
40.0 |
±2.10 | |
|
4.0 |
±0.45 |
45.0 |
±2.30 | |
|
4.5 |
— |
50.0 |
±2.45 | |
|
5.0 |
±0.52 |
|
| |
|
Note: 1. The other tolerances are negotiated by customer and supplier.
2. The tolerance of preferred thickness should adopt the bigger one if the one of preferred thickness for nominal thickness is not listed in the table.
3. Normal dimension: 960±15mm×1460±15mm、960±15mm×1960±15mm | ||||
Table 2:Technical requirements
|
No |
Property |
Unit |
Normal Value | |||
|
1 |
Flexural strength perpendicular to layer |
At room temperature |
MPa |
≥340 | ||
|
150±2℃ | ||||||
|
2 |
Apparent flexural elastic modulus |
MPa |
≥(24000) | |||
|
3 |
Compressive strength, perpendicular to layer |
MPa |
≥350 | |||
|
4 |
Impact strength parallel to layer (Charpy method) |
kJ/m2 |
≥33 | |||
|
5 |
Impact strength parallel to layer.(Cantilever beam method) |
kJ/m |
≥34 | |||
|
6 |
Shear strength, parallel to the layer |
MPa |
≥(30) | |||
|
7 |
Tensile strength |
Lengthwise |
MPa |
≥(300) | ||
|
Crosswise | ||||||
|
8 |
Electric strength,perpendicular to the layer(at 90℃±2℃ oil.) |
MV/m |
Refer to table 3 | |||
|
9 |
Breakdown voltage, perpendicular to layer direction. |
kV |
≥35 | |||
|
10 |
Dielectric constant |
Under 48Hz~62Hz |
— |
≤5.5 | ||
|
under1Hz |
— |
≤5.5 | ||||
|
11 |
Dissipation factor |
Under 48Hz~62 Hz |
— |
≤0.04 | ||
|
Under 1MHz. |
— |
≤0.04 | ||||
|
12 |
Insulation resistance after immersing in water. |
W |
≥5.0×108 | |||
|
13 |
Comparative tracking index. |
— |
≥(200) | |||
|
14 |
Heat resistance for long time. |
— |
≥(130) | |||
|
15 |
Matin`s temperature |
℃ |
under consideration | |||
|
16 |
Density |
g/cm3 |
1.7~1.9 | |||
|
17 |
Water absorption |
% |
Refer to table 4 | |||
|
Note: The value in the parentheses for Type 3240 is typical value. Not used as the requirement only for reference. | ||||||
Table 3: Electrical strength perpendicular to layer direction
|
Mean thickness
mm |
Normal Value Unit: MV/m |
|
Mean thickness
mm |
Normal Value Unit: MV/m |
|
0.2 |
- |
1.4 |
≥13.2 | |
|
0.3 |
- |
1.6 |
≥12.7 | |
|
0.4 |
≥16.9 |
1.8 |
≥12.2 | |
|
0.5 |
≥16.1 |
2.0 |
≥11.8 | |
|
0.6 |
≥15.6 |
2.2 |
≥11.4 | |
|
0.7 |
≥15.2 |
2.4 |
≥11.1 | |
|
0.8 |
≥14.8 |
2.5 |
≥10.9 | |
|
0.9 |
≥14.5 |
2.6 |
≥10.8 | |
|
1.0 |
≥14.2 |
2.8 |
≥10.5 | |
|
1.2 |
≥13.7 |
Above 3.0 |
≥10.2 |
Table 4:Water absorption
|
Mean thickness
mm |
Normal Value Unit:mg |
|
Mean thickness
mm |
Normal Value Unit:mg |
|
0.4 |
≤17 |
5 |
≤25 | |
|
0.5 |
≤17 |
6 |
≤27 | |
|
0.6 |
≤17 |
8 |
≤31 | |
|
0.8 |
≤18 |
10 |
≤34 | |
|
1.0 |
≤18 |
12 |
≤38 | |
|
1.2 |
≤18 |
14 |
≤41 | |
|
1.6 |
≤19 |
16 |
≤46 | |
|
2.0 |
≤20 |
20 |
≤52 | |
|
2.5 |
≤21 |
25 |
≤61 | |
|
3 |
≤22 |
Processed by one side to 22.5 |
≤73 | |
|
4 |
≤23 |
|
|