Temperature classification is H. High heat resistance and excellent mechanical property. Used as slot and wedge for Class H pulling motors and huge motors as well as insulating structural parts with heat resistance for top-technical apparatus.
Table 1:Nominal thickness and tolerance
Nominal thickness
mm |
Normal Value
mm |
|
Nominal thickness mm |
Normal Value
mm |
0.2 |
±0.07 |
5.0 |
±0.48 | |
0.3 |
±0.07 |
5.5 |
±0.48 | |
0.4 |
— |
6.0 |
±0.58 | |
0.5 |
±0.14 |
6.5 |
±0.58 | |
0.6 |
— |
8.0 |
±0.68 | |
0.8 |
±0.14 |
10.0 |
±0.80 | |
1.0 |
±0.22 |
12.0 |
±1.00 | |
1.2 |
±0.22 |
14.0 |
±1.00 | |
1.5 |
±0.22 |
16.0 |
±1.30 | |
1.6 |
— |
20.0 |
±1.30 | |
1.8 |
±0.28 |
25.0 |
±1.50 | |
2.0 |
±0.28 |
30.0 |
±1.50 | |
2.5 |
±0.33 |
35.0 |
±2.00 | |
3.0 |
±0.33 |
40.0 |
±2.00 | |
3.5 |
±0.33 |
45.0 |
— | |
4.0 |
±0.38 |
50.0 |
— | |
4.5 |
±0.38 |
|
| |
Note: 1. The other tolerances are negotiated by customer and supplier.
2. The tolerance of preferred thickness should adopt the bigger one if the one of preferred thickness for nominal thickness is not listed in the table.
3. Normal dimension: 960±15mm×1460±15mm、960±15mm×1960±15mm |
Table 2:Technical requirements
No. |
Properties |
Unit |
Normal Value | |||
1 |
Flexural strength perpendicular to layer |
At room temperature |
MPa |
≥400 | ||
150±2℃ |
≥280 (180±2℃) | |||||
2 |
Impact strength parallel to layer (Charpy method) |
kJ/m2 |
≥50 | |||
3 |
Voltage resistance, perpendicular to the layer(at 90℃±2℃ oil.) |
|
Refer to table 3 | |||
4 |
Dissipation factor |
Under 48Hz~62 Hz |
— |
≤0.05 | ||
Under 1MHz. |
— |
- | ||||
5 |
Voltage resistance parallel to layer(at 90℃±2℃ oil for 1min) |
kV |
≥30 | |||
6 |
Volume resistivity |
At room temperature |
MW |
≥1.0×105 | ||
Immersing in water for 24h |
≥1.0×103 | |||||
180℃±2℃ |
≥1.0×103 | |||||
7 |
Surface resistivity |
At room temperature |
MW |
≥1.0×106 | ||
Immersing in water for 24h |
≥1.0×104 | |||||
180℃±2℃ |
≥1.0×104 | |||||
8 |
Bonding strength |
N |
≥180 | |||