| NO. | Test Item | Criterion | |
| 1 | Voltage | Charging Voltage | 42.5V 4.25×10 |
| Balance Voltage | 4.20±0.025V | ||
| 2 | Current | Balane Current | 84±10MA |
| Current Consumption for single cell | ≤100UA | ||
| Maximal continuous discharge current | 20A | ||
| 3 | Over Charge Protection | Over charge detection current | 4.20~4.35±0.025V adjustable |
| Over charge detection delay time | 2-16320 MS adjustable | ||
| Over charge release voltage | 4.00~4.20±0.05V | ||
| 4 | Over discharge protection | Over charge detection voltage | 2.00~3.00±0.1V adjustable |
| Over discharge protection delay time | 1~16S adjustable | ||
| Over charge release voltage | 2.000~3.00V | ||
| 5 | Over current protection | Over current dectection voltage | 0.05~0.30V |
| Over current dectection current | 50±5A | ||
| Detection delay time | 8-32768 US adjustable | ||
| Release condition | cut load | ||
| 6 | Short Protection | Detection condition | exterior short circuit |
| Detection delay time | 33~89US adjustable | ||
| Release condition | cut short circuit | ||
| 7 | Resistance(MOSFET) | (MOSFET) | ≤4mΩ |
| 8 | Temperature | P[erating temperature Range | -40~80℃ |
| Storage temperature range | -40~120℃ | ||