| NO. |
Test Item |
Criterion |
| 1 |
Voltage |
Charging Voltage |
55.25V 4.25×13 |
| Balance Voltage |
4.20±0.025V |
| 2 |
Current |
Balane Current |
84±10MA |
| Current Consumption for single cell |
≤100UA |
| Maximal continuous discharge current |
20A |
| 3 |
Over Charge Protection |
Over charge detection current |
4.20~4.35±0.025V adjustable |
| Over charge detection delay time |
2-16320 MS adjustable |
| Over charge release voltage |
4.00~4.20±0.05V |
| 4 |
Over discharge protection |
Over charge detection voltage |
2.00~3.00±0.1V adjustable |
| Over discharge protection delay time |
1~16S adjustable |
| Over charge release voltage |
2.000~3.00V |
| 5 |
Over current protection |
Over current dectection voltage |
0.05~0.30V |
| Over current dectection current |
50±5A |
| Detection delay time |
8-32768 US adjustable |
| Release condition |
cut load |
| 6 |
Short Protection |
Detection condition |
exterior short circuit |
| Detection delay time |
33~89US adjustable |
| Release condition |
cut short circuit |
| 7 |
Resistance(MOSFET) |
(MOSFET) |
≤4mΩ |
| 8 |
Temperature |
Operating temperature Range |
-40~80℃ |
| Storage temperature range |
-40~120℃ |