| No |
Test Item |
Criterion |
| 1 |
Voltage |
Charging Voltage |
17V 4.25×4 |
| Balance Voltage |
4.20±0.025V |
| 2 |
Current |
Balane Current |
210±30MA |
| Current Consumption for single cell |
≤30UA |
| Maximal continuous discharge current |
35A |
| 3 |
Over Charge Protection |
Over charge detection current |
3.85±0.025V~4.40±0.025V |
| Over charge detection delay time |
1.0 ±0.6S |
| Over charge release voltage |
3.800~4.40V |
| 4 |
Over discharge protection |
Over charge release voltage |
2.0±0.080V~3.0±0.080V adjustable |
| Over discharge protection delay time |
100±60MS |
| Over charge release voltage |
2.000~3.40V |
| 5 |
Over current protection |
Over current dectection voltage |
0.05~0.30V |
| Over current dectection current |
80-120A |
| Detection delay time |
10±4MS |
| Release condition |
Cut load |
| 6 |
Short Protection |
Detection condition |
Exterior short circuit |
| Detection delay time |
100-600US |
| Release condition |
Cut short circuit |
| 7 |
Resistance(MOSFET) |
(MOSFET) |
≤2mΩ |
| 8 |
Temperature |
P[erating temperature Range |
-40~80℃ |
| Storage temperature range |
-40~120℃ |