Product Main

Specifications

 Phase Rotation Indicator:
Model: Phase Detector ETCR1000A
Category: Phase Detector

Phase Detector Illustration:

ETCR1000A is a phase detector, designed to perform phase sequence checks and live line checks of a 3-phase circuit using a static induction voltage clip.

1. The static induction voltage clips are used to be able to clip on a cladded wire.
2. It is small with a CAT III 600V safety rating.
3. Red LED lamps are used to make the indication visible in dimly lit areas.
4. The direction of phase sequence can be checked easily using the LED lamps, which blink in order.
 
Basic Specifications

Function
Phase detection (positive/negative)
Voltage detection method
Static induction
Object to be connected
Insulated wire (nominal sectional area of the conductor: 2 to 100 mm2, finished outer diameter: up to ? 17mm)
Performance-guarantee voltage range
3-phase, 70 to 600 VAC (sine wave,continuous)
Operating frequency range
45 to 66 Hz

Display

Phase-detection indication
Positive phase sequence:
The four phase-sequence lamps blink order (clockwise) and the buzzer sounds intermittently.
Negative phase sequence:
The four phase-sequence lamps blink in order (counterclockwise) and the buzzer sounds continuously.
Line-voltage indication
R-S lamp, S-T lamp
Power indication
Power ON lamp: lights up (Power ON)
blinks (Battery Low)

General Specifications

Operating temperature and humidity
0 to 40℃(32 to 104℉), 80%RH or less ( with no condensation)
Storage temperature and humidity
-20 to 60℃(-4 to 140℉), 80%RH or less (with no condensation)
Location for use
Altitude up to 2000m(6562 feet), indoors
Maximum rated voltage to earth
600V
Dielectric strength
5.4kVrms
Power supply
Rated supply voltage 1.5VDC×2  Two "AA” size batteries
Maximum rated power
300Mva
Continuous operating time*
Approx.70 hours(Power ON, Standby state, using R6P manganese battery) *Battery life
Auto Power Off
(This function can not Be canceled.)
The power will be turned off automatically if the Instrument remains idle for 15 minutes after the power is turned on. To reset, turn the power on again using the Power ON switch.
Options
Carrying case, Strap*, Spiral tube*, Instruction manual, Two R6P manganese batteries. *Attaching as the occasion demands.
Cable length
Approx.0.7m(27.56)
Dimensions and mass
Approx.70W×75H×30Dmm(2.76W×2.95H×1.18D)
 (excluding projections), Approx.200g(7.1oz)
Applicable standards
Safety EN61010-1:2001,EN61010-031:2002
Pollution degree2, Measurement category CAT III(600V)(anticipated transient overvoltage 6000V)
EMC EN61326:1997+A1:1998+A2:2001