Description:
1. DIESEL GENERATOR SETS:
Diesel generator set include diesel engine, alternator, control box, chassis connecter, battery, silencer Canopy, spare parts, kit, manuals.
2. CONTROL SYSTEM:
Apparatus: voltmeter, frequency meter, amperage meter, voltage of battery, meter of water
temperature, oil pressure meter.
Control section: starting switch and button, inductive type self-protection switch, and
indicator.
3. Option function:
(1) A. T.S. Control panel (when electric supply has been stopped, the gen-sets can start three
times automatically in 3-28 seconds (time can be adjustable) between electric supply and
every time need 6-8 seconds. It will spend 12 seconds to accept load when electric supply
is resumed, gen-set will maintain 23-230 seconds, then closes down automatically);
(2) A. M.F. Control panel (Automatic startup/shutdown, and four protection system);
(3) Four protection system (alarm and shutdown to low oil pressure, high coolant
temperature, emergency stop and over-speed).
|
Model of Gen-set |
Unit |
GF10-LDE |
GF12-LDE |
GF15-LDE |
GF20-LDE |
GF24-LDE |
GF-LDE |
GF40-LDE |
GF50-LDE |
GF64-LDE |
GF75-LDE |
GF100-LDE |
|
Rated power |
KW |
10 |
12 |
15 |
20 |
24 |
30 |
40 |
50 |
64 |
75 |
100 |
|
Diesel |
Model |
|
295AD |
295AD |
395AD |
495AD |
495AD |
495AZD |
R4100ZD |
R4105ZD |
R6015ZD |
R6015ZD |
R6135ZD |
|
Engine |
12Hours Ratedoutput |
KW/PS |
13.2/18 |
14.7/20 |
19.7/27 |
26.5/36 |
26.5/36 |
36.7/50 |
48/66.0 |
55.8/76 |
85/116.0 |
85/116.0 |
139.7/190 |
|
|
Fuel Consumption |
g/kw. H |
246.2 |
248.2 |
252.2 |
258.4 |
258.4 |
251.6 |
251.6 |
231.1 |
228.4 |
228.4 |
232.8 |
|
|
Cooling Method |
|
water cooled |
water cooled |
water cooled |
water cooled |
water cooled |
water cooled |
water cooled |
water cooled |
water cooled |
water cooled |
water cooled |
|
|
Starting Method |
|
electric starting |
electric starting |
electric starting |
electric starting |
electric starting |
electric starting |
electric starting |
electric starting |
electric starting |
electric starting |
electric starting |
|
Generator |
Model |
|
TFW-10 |
TFW-12 |
TFW-15 |
TFW-20 |
TFW-24 |
TFW-30 |
TFW-40 |
TFW-50 |
TFW-64 |
TFW-75 |
TFW-100 |
|
Rated Output |
KW |
10 |
12 |
15 |
20 |
24 |
30 |
40 |
50 |
64 |
75 |
100 |
|
|
Rated Voltage |
V |
400/230 |
400/240 |
400/230 |
400/230 |
400/230 |
400/230 |
400/230 |
400/230 |
400/230 |
400/230 |
400/230 |
|
|
Rated Current |
A |
18.1 |
21.7 |
27.1 |
36 |
43.3 |
54 |
72 |
90.2 |
115 |
135 |
180 |
|
|
Frepuency |
HZ |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|
|
Rower Factor |
|
0.8lagging |
0.8lagging |
0.8lagging |
0.8lagging |
0.8lagging |
0.8lagging |
0.8lagging |
0.8lagging |
0.8lagging |
0.8lagging |
0.8lagging |
|
|
Phase Connection |
|
3phase, 4 wire |
3phase, 4 wire |
3phase, 4 wire |
3phase, 4 wire |
3phase, 4 wire |
3phase, 4 wire |
3phase, 4 wire |
3phase, 4 wire |
3phase, 4 wire |
3phase, 4 wire |
3phase, 4 wire |
|
|
Exciation |
|
brushness |
brushness |
brushness |
brushness |
brushness |
brushness |
brushness |
brushness |
brushness |
brushness |
brushness |
|
Control |
Model |
|
BF-S-10 |
BF-S-12 |
BF-S-15 |
BF-S-20 |
BF-S-24 |
BF-S-30 |
BF-S-40 |
BF-S-50 |
BF-S-64 |
BF-S-75 |
BF-S-100 |
|
Panel |
Voltage Regulation |
|
manul/automatic |
manul/automatic |
manul/automatic |
manul/automatic |
manul/automatic |
manul/automatic |
manul/automatic |
manul/automatic |
manul/automatic |
manul/automatic |
manul/automatic |
|
Net Weight |
kg |
550 |
560 |
580 |
650 |
680 |
780 |
1000 |
1350 |
1650 |
1750 |
2000 |
|
Gross Weight |
kg |
620 |
630 |
680 |
760 |
780 |
830 |
1150 |
1500 |
1800 |
1900 |
2100 |
|
Packing Size LxWxH |
mm |
1500x710x1100 |
1500x710x1100 |
1650x720x1150 |
1850X730X1250 |
1850X730X1250 |
1850X730X1250 |
2200X750X1400 |
2300X920X1500 |
2600X1000X1500 |
2850X1000X1650 |
2950X1000X1650 |