YT building use water paint which is antibacterium, rot resistance
Use methods
◆ It can used by brush coating, roller coating, spray coating and high pressure air-free coating. It is recommended to use spray gun with the 2mm diameter of nozzle。
◆ It can be diluted by water, the maximum is 20%, while diluting, please stir to mix thoroughly
◆ The dosage: Theoretically, 8 square meter per kilo (once); actually, it changes while the construction way different and the surface roughness different.
◆Drying time: surface drying time 30 minutes, under standard condition (temperature: 23℃±2, relative humidity 50%±5), actual drying time is 2 hours. Re-coating time 3 hours (changes while the environmental temperature and humidity changes)
The requirements of construction
1. The basic level should be firm, clean and oil-free, moisture content <10%, PH < 10
2. The basic level should be sealed first, it’s better to use our match products P-01 Alkali-resistant seal coat.
2. The basic level should be sealed first, it’s better to use our match products P-01 Alkali-resistant seal coat.
3. Environmental temperature should over 5℃, and the humidity under 85%.
4. All tools should be cleaned immediately by water or detergent while finished.
Storage procedures
1. It should be stored in a cool, clean and dry place; the temperature should between 2℃~35℃.
2. It should be tightly closed immediately after finished,
3. packing untapped, the shelf life is 12 months.