Product Main

Specifications

HYBOND 303 UV adhesive
 Description
Fast curing, high strength Ultra Violet adhesive, specially designed for bonding glass to metal, even                     Glass to Aluminum cake and glass to Stainless Steel bonding in the manufacturing of glass and crystal furniture.
It’s suitable for safety glass and color glass (partly UV radiation absorbing).
Physical properties
Composition: methacrylate ester
Color: colorless
Viscosity (Brookfield 25°C–mPa.s): 600 - 1300
Specific weight (g/ml): 1.1 and 1.4
Curing time UV (365 nm): 8 – 15 seconds
Gap to fill: from 0.03 mm to 1.5 mm
Flash point: > 100°C
Shelf life: 1 year
Main Performance(Glass/Metal):

 

Items
Performance
Type
HYBOND 303Uv Adhesive
 
303(2)UV adhesive
 
 
 
Color
Clear or yellowish
Clear
 
 
 
Viscosity 25 ℃
650-700 MPa.s
3000±500
 
 
 
Solidify time
About 10s
About 10s
 
 
 
Refraction
1.47-1.50
1.47-1.50
 
 
 
Storage
Room temperature , avoid sunlights.
 
 
 
Curing properties
For better strength and durability we recommend to clean, degrease and dry surfaces to bond. The polymerisation UV belongs to the intensity of the UV lamp, to the distance from the UV light source, to the bondline gap and to the light transmittance of the substrate the light shall pass through. We recommend high inensity UV light sources with minimum radiation between 365 nm and 420 nm at 100mW/cm2., curing time may vary according to adhesive gap.
Properties of cured adhesive
* Tensile strength (ASTM D-2095-69): 10 - 14 N/mm²
* Temperature range: -55°C + 120°C
* Refractive index: 1.49
* Light transmittance: > 98%
* Coefficient of thermal expansion: 85 x 10-6 mm/mm/°C
* Dieletric constant (25°C 1000 Hz): 4
* Dieletric strength 10-12 KV/mm
Storage
Keep product in a cool and dry room at +28°C. To avoid contaminations do not refill containers with used product. For more information on applications, storage and handling contact HYBOND Technical Service
 
Note
The data contained herein, obtained in HYBOND laboratories, are given for information only. HYBOND cannot assume responsibility for the results obtained by others which methods are not under HYBOND control. It is the user's responsibility to determine suitability for the user's purpose of any product mentioned herein. HYBOND disclaims all warranties expressed or implied, including warranties of merchantability or fitness for a particular purpose, arising from sale or use of HYBOND products. HYBOND specifically disclaims any liability for consequential or incidental damages of any kind, including lost profits.