Manual Data Sheet Software
Features:
- Six high speed operation modes: CC, CR, CV, CW, CC+CV, CR+CW
- Over current, over voltage, over power, over heat, polarity reversed protection
- High-luminance VFD screen with two lines& four channels display
- Intellegent fan system fan will be automatically initiated according to the temperature
- Soft start time setting, carrying the power supplier according to the voltage value set
- Battery testing and short-circuit function
- Available of dynamic testing and rising edge and falling edge setting
- Supporting external trigger input and output
- External current waveform monitor terminal
- Supporting remote voltage compensation and multidata storage
- Power-on-self-test, software calibration and standard rack mount
- Communication mode: GPIB/RS232/RS485/USB.
Application:
Production line(cell phone charger, cell phone battery, electric vehicle battery, switching power supplier, linear power supplier), research insititutes, automotive electronics, aeronautics and astronautics, ships, solar cells fule cell, etc.
Specification:
| Model |
M9713 |
| Input Rating |
Power |
600W |
| Current |
0-120A |
| Voltage |
0-150V |
| CC Mode |
Range |
0-12A |
0-120A |
| Resolution |
1mA |
10mA |
| Accuracy |
0. 05%+0. 05%FS |
0. 1%+0. 05%FS |
| CV Mode |
Range |
0. 1-19. 999V |
0. 1-150V |
| Resolution |
1mV |
10mV |
| Accuracy |
0. 03%+0. 02%FS |
0. 03%+0. 02%FS |
| CR Mode |
Range |
0. 03-10K Oh |
0. 03-5K Oh |
| Resolution |
16 bit |
16 bit |
| Accuracy |
0. 1%+0. 1%FS |
0. 1%+0. 1%FS |
| CW Mode |
Range |
0-600W |
0-600W |
| Resolution |
1mW |
10mW |
| Accuracy |
0. 1%+0. 1%FS |
0. 1%+0. 1%FS |
| Voltage Measurement |
Voltage |
0-19. 999V |
0-150V |
| Resolution |
1mV |
10mV |
| Accuracy |
0. 015%+0. 03%FS |
0. 015%+0. 03%FS |
| Current Measurement |
Current |
0-12A |
0-120A |
| Resolution |
0. 1mA |
1mA |
| Accuracy |
0. 05%+0. 05%FS |
0. 1%+0. 08%FS |
| Power Measurement |
Power |
100W |
600W |
| Resolution |
1mW |
10mW |
| Accuracy |
0. 1%+0. 1%FS |
0. 1%+0. 1%FS |
| Battery Test |
Battery Input: 0. 1-150V; Max. Measurement: Capacity=999AH; Resolution=0. 1mA; Time Range=1S-16H |
| Dynamic Test |
Transition Lsit: 0-25kHZ; 2. 5A/uS; T1& T2: 60uS-999S; Accuracy: +15% offset+10%FS |
| Current soft-startup Time |
1mS; 2mS; 5mS; 10mS; 20mS; 50mS; 100mS; 200mS; 500mS; 1000mS Accuracy: +15% offset+10%FS |
| Short Circuit |
Current(CC) |
=13. 2A |
=132A |
| Voltage(CV) |
0V |
| Resistance(CR) |
=13mOh |
| Temperature |
Operating |
0~40oC |
| Nonoperating |
-10oC~70oC |
| Dimension |
W*H*D(mm) |
428*103. 5*453. 5 |
| Weight |
Kg |
17. 6 | |