BZB-8700 SPRAY BOOTH
|
Outside Size (mm) |
7040×5500×3450 |
Front Door(mm) |
3000(w)×2600(H) |
|
Inside Size(mm) |
6900×4000×2650 |
Total Power(km) |
30 |
|
Cabin System |
Wallboard |
EPS (epispastics polystyrene)Colorful Steel Skin Boards, 70mm Thick, Ceiling panel:50mm thick. The side door with a pressure lock which will automatically open when the pressure inside is over-pressure. | ||
|
Basement |
Full Grid, Adjustable Height, Galvanized Steel Sheet Construction, Three Embossed Steel Ramps | |||
|
Air Circulation System |
Inlet Fan |
Model: YDW 4.5L1 |
Outlet Fan |
Model: 4-82-6.3E |
|
Capacity: 24000m3/h |
capacity: 30000m3/h | |||
|
Pressure: 800Pa |
Pressure: 1236Pa | |||
|
Power: 4kw |
Power: 15kw | |||
|
Quantity: 2 sets |
Quantity: 1set | |||
|
The circulation system covers a set of automatic valve and two sets of manual valve. Manual adjustment valves are placed in inhaling and exhaust duct to control airflow volume and adjust pressure. A stainless steel trapezoid hood and a stainless cone hood | ||||
|
Purification System |
Dual Filtering Structure, The Primay Filter Can Capture Granules Larger than 10μm. Ceiling Filter Capture Granules Bigger than 4μm. Its filtering rate reaches 98%. air pressure balance gauge, TSP≤1.2mg/m3 | |||
|
Heating System |
Burner |
Italy Riello Brand, RG5S Diesel Burner, 260000Kcal/h, 20N Damp Motor 2 sets quick dryer. | ||
|
Heat Energy Converter |
SUS304 Stainless Steel heat exchanger, argon arc welding, heat exchange rate 85%; | |||
|
Max Temp:80℃, Heating Time:4-6min(20-60℃), Fuel Consumption: 6-8kg/vehicle | ||||
|
Light System |
Ceiling Light: 32 pcs 36w Philips Lamp; Bottom Light: 32 pcs 20w Philips Lamp, 1100 Lux | |||
|
Controlling System |
PLC controlling, soft touching button, Spray & Baking Switch, Light Switch, Emergency Stop, Breakdown Alarm, Failure alarm, timer | |||
|
Environmental System |
No-pump water curtain for mist filtering device can reduce more than 98% of the fog without the trouble of replacing drying-method filter by fully mixing fog, water and air, and ensure a qualified exhaust according to the relevant state standards | |||