Patient Monitor PM-60D(ECG,Spo2,NIBP,PR)
Features:
■ Routine Check Mode and 
       Continuous Monitoring Mode
■ Data Graph and Trend Table 
       Review
■ Rich Analysis Report
■ Perfect Mount Solution
■ Convenient operation by touch screen
■ Large SD card memory for more than 
       2000 patient cases storage
■ Sync with PC based Sofrware (WinXP and WinVista)
Performance Specifications:
■ Display:3.5" Color TFT
■ Resolution:320x240
■ Display Mode:Standard face, Waveform face, SPO2 view, 
       ECG view, BigNum view                  
■ Indicator:Power indicator light, Alarm sound, Pluse tone
■ Interface:One dual-purpose socket for connecting sensors  
       and communication cables
■ Power Supply:DC 5V, <500MA
■ Battery:Builtin Li-Polymer, 2 hours for charging, 3 hours 
■ for continous working.10 hours for standby mode
■ Trend Graph:Resolution from 1s, 5s, 10s. Maximum time 
        96 hours.
■ Trend Table:Resolution from 1s, 5s, 10s. Review up to 1000 
        items.
■ Alarm:Ajustable High and Low limits. Three level au
       dible and vistual alarm 
■ User Configuration:All the color of parameters and waves 
       can be set according to user's willing
Technical specifications:
■ Safety
■ Meet the requirment of IEC60601 series
■ Type of Protection:Class II with internal electirc power 
       supply
■ Degree of Protection:BF
■ Dimention and Weight
■ Dimention:92(W)x82(H)x22(D)mm
■ Weight:136g(with battery)
■ Operation Environment:
■ Temperature:0℃~ +40℃
■ Humidity:15% ~ 95%
■ Storage Environment:
■ Temperature:-20℃~ +60℃
■ Humidity:10% ~ 95%         
■ Patient Range
■ Neonate ,Pediatric and  Adult
SPO2:
■ Measurement Range:0 ~ 100%
■ Resolution:1%
■ Accuracy:±2%(70%~100%, Adult/Pediatric, non-motion)
                  ±3%(70%~100%, Neonate, non-motion)
                0% ~ 69% unspecified
■ Alarm Range:0% ~ 100%
■ Refreshing Rate:1s
Pulse Rate:
■ Measurement Range:25 ~ 250 bpm
■ Resolution:1bpm
■ Accuracy:± bpm (non-motion)
■ Alarm Range:25 ~ 250 bmp
■ Refreshing Rate:1s
ECG:
■ Lead mode:3-lead or 5-lead
■ Lead selection: I, II, III, AVR, AVL, AVF, V
■ HR range:15 ~ 300 bpm
■ ECG Waveform:2 channals
■ Accuracy:±2bpm or ±2%, which is greater
■ S-T segment detection, range: -2.0mv ~ +2.0mv
■ Arrhythmia analysis: 13 kinds of arrhythmia
■ Alarm Range:15 ~ 300 bpm
NIBP:
■ Method:Oscillometry
■ Mode:Manual/Auto/Contiuous
■ Measurement Range:25 ~ 260mmHg
■ Atuo Measure Interval: 5, 10, 15, 30, 45, 60, 90 
       minutes
■ Resolution:1mmHg
■ Overpressure Protection: 300mmHg
■ Alarm range:25 ~260mmHg