HD-10B Power Plug Integrated Tester
Product explanation: This tester is an integrated tester for plug. It is used to test the continuity, insulation, high-volt, leakage current of power plug. It meets the requirements of many international standards such as BIS, UL, CSA, VDE, BSI, DIN, CCC, IEC, etc. It is automatic testing machine make your operation more convenient and simple.
Features:
* All of the test subjects will be done automatically.
* The inner/outer high-volt output value and persistence time can be adjusted separately.
* Test speed very quick, all test subjects will be achieved less than 2 seconds.
* The PLC control system is come from Mitsubishi, Made In Japan.
* The relay is come from Schneider, Made In French.
* If the specimen is incompetent, there is an alarm by buzzer and light.
* If the specimen is incompetent, this machine will stop at once and show you which subject is incompetent. After you push the emergency button it will restart a new test. And a switch with key can be made to order to replace the high-volt starting button, it is very useful, because when a alarm happen, the operators can not restart this machine, only after the managers have checked over and restart it by key the machine will be working again.
* When test over, the sample will be pushed out automatically, and a "T" or other characters will be marked on it (English characters only).
* Cord set which both have a plug and socket can be tested by this machine.
Technical parameter:
Polarity test: Test E, L, N wires in sequence
Insulation test high-volt: DC 500V +-10%
Insulation resistance: 2, 7, 20, 50, 100MΩ (can be made to order)
Inner high-volt: 0~5KV +-5% (adjustable)
Outer high-volt: 0~5KV +-5% (adjustable)
Leakage current: 0.5, 1, 3, 5, 10mA (can be made to order)
Rated power: 500VA
Cylinder power: compressed air with 0.4 to 0.6Mpa
Dimensions: 750mm W, 540mm D, 520mm
H Power source: AC 220V +-10%, 50Hz
Weight: 40kg, approximate
NOTICE:
1. Inner high-volt is applied between L, N, E wires, and the outer high-volt is applied between L, N, E wires and jacket.
2. Both 3-wire and 2-wire power plug can be tested by this machine.