Product Main

Specifications

1.thread:18MM,reach 21MM,hex 22MM,total legth113MM,double ridium for the electrod.
2.runtime over 3000 hours.
3.resistor according to national standand as 2-12Kohm.
 
APPLICATIONS
Commonly used in the following engines
CaterpillarTM-All 3500 and all G3600 Series
 WaukeshaTM-VGF, VHP. GL, GSI, others
 SuperiorTM-1706G2, 1721G1, 2400 G Series, others
 Several Other Engines
High grade replacement for Champion RB77WPC and KB77WPCC, Cat 194-8518, and Waukesha 60999z, BOSCH 7306 EXTREME DUTY PLUG
 Cat 194-8518 and Waukesha 60999z aremade by ChampionTM
Compares favorably with, but less expensive than, Cat biogas plug 243-4291 and Waukesha long-life 69919D
 Both made by DensoTM

TECHNICAL FEATURES
Highly upgraded plug from current offering in the market
2.0k-ohm graphite-encased resistor
 Long life and compatibility with EIS ignition systems
Improved state-of-the-art precious metals alloy insert
 Handles extreme cylinder temperatures and insures extended plug life
New hardened ground strap
 Prevent opening under high extended periods of high temperature
Center and ground electrodes resist deposit buildup
 Cleaning is required less often
Thicker porcelain
 Provides more strength
 Resists cracking and thermal punctures
Specially designed crush washer
 More torque retention at 30 ft-lb than competition at 50 ft-lb
 Reusable
Over all mechanical structure superior to competition.

PERFOMANCE IN CATERPILLARTM 3600 SERIES
Testing done in G3606 thru G3616
 Highly loaded engines-over 100%
750 to 1200hr runtime with CaterpillarTM 194-8518
3000 hr runtime with Bosch 7306, consistently
 Runtime achieved without removal for cleaning
Improved ground strap stability

PERFORMANCE IN WAUKESHATM 7044
Engine loaded at maximum capacity
Control panel reading 14050exhaust temp
1200 hr maximum runtime with Cater pillarTM194-8518
 Experiencing single plug failures 700 hr and ground strap opening
Over 5000 hr runtimes with Bosch 7306

PERFORMANCE IN SUPERIORTM2408
700 hr runtime with CaterpillarTM194-8518
 Customer experiencing single plug failures within 21 days
Bosch benchmark for runtime was 2000 hr
Pictures at right are at 4400 hr runtime
Plugs were still operating when they were replaced
 Customer changed plugs while replacing leaking pre-chamber assemblies