Product Main

Specifications

GS301 load cells are available in the manifold accurate measurement in the capacities 50kgs to 300kgs. Alloy steel and stainless steel, hermetically sealed, oil-proof, waterproof and anti-corrosion, suitable for multiform environments. Single point structure, suitable for electronic scale, electronic platform scale, belt scale and other electronic weighing devices. Recommended platform dimension: 600×< Xml: namespace prefix = st1 ns = "urn: schemas-microsoft-com: office: smarttags" />600mm. Low profile and easy installation.

Technical Parameter:

Rated load

50/100/200/300kg

Sensitivity

(2. 0±0. 1%) mV/V

Combined error

±0. 03% F. S

Creep Error(30min)

±0. 03% F. S

Zero balance

±1% F. S

Temp. Effect on zero:

±0. 02% F. S/10℃

Temp. Effect on Span:

±0. 02% F. S/10℃

Input resistance:

385±5Ω

Output resistance:

353±2Ω

Insulation resistance:

≥5000MΩ

Operating Temperature Range

-30~+70℃

Maximum safe over load:

150%F. S

Ultimate over load:

200%F. S

Recommend excitation voltage:

10~12V DC

Maximum excitation voltage:

15V DC

Sealing Class:

IP68

Element material:

Stainless steel

Cable:

Length=L: 3m

Citation

GB/T7551-1997/ OIML R60

Mode of Connection

Red(Input+), Black(Input-), Green(Output+), White(Output-)t-)