Product Main

Specifications

Nk6-1A Auxiliary switch

It applies to AC vacuum contactor, solenoid switch, contactor, breaker and so on.Item NK3-1 includes three make-break contacts, and item NK2-1(A) includes two make-break contacts( A refers to timelag). If one of these contacts is broke after its contacted, the time of timelag should be no less than 0.3mm.

Electrical Load

 

Current Type

On-condition

Off-condition

Voltage(V)

Current(A)

cosφ

T0.95ms)

Voltage(V)

Current(A)

cosφ

T0.95ms)

AC

380

15

0.7±0.05

 

380

1.5

0.4±0.05

 

DC

220

0.55

 

300±45

220

0.55

 

300±45

Action Options

 

Item Max. Actuating length(mm) Min. Contact over travel (mm Min. Delayed length (mm) Max. Actuating force (N) Min. Contact Force (N)
NK6-1 8-10 2.5-3.5   20 0.8
NK6-1 A 8-10 2.5-3.5 0.5 20 0.

Electric rating value

AC: 380V, 5A; 220V, 10A; 110V, 15A

DC: 27V, 10A

Electric Life ≥30×104

Mechanical Life≥10×10 5

Customization is available.

Please don't hesitate to contact us if you have any question.