H/L Voltage Clamp Meter
Model: ET-9000
 
ET-9000 Series H/L Voltage Clamp Meter has broken through the traditional structure, which is specially well-designed for measuring high voltage current, adopting the latest CT technology and integrated mask digital technology, formed by composition of a special use clamp meter with a high-voltage insulation rod, as to ET-9000A type ---- infrared transmission of test data, also equipped with receivers, which can monitor the tested data in a long distance on real-time. If not using an insulation rod, it can be also used as a high precision low-voltage clamp meter, or an alternating current meter, which can accurately measure1mA of current or leakage current.
 
2.Technical Specifications
Function
High voltage AC current measurement, low voltage AC current, leakage current measurement, on-line AC current supervision.
Power Supply
DC6V Alkaline Battery (1.5V AAA X 4)
Test Method
Clamp CT, Integral Method
*Transmission Method
Infrared Transmission, the maximum distance for direct transmission is about 30m.
Display Mode
4 digital LCD display, backlight function, suitable for dark place.
LCD Dimension
47mm x 28.5mm
Meter Dimension
W/H/T: 76mm×255mm×31mm
Clamp Diameter
φ48mm
Sampling Speed
Around 2 times/second
Measurement Scope
0.1mA to 1000A(50/60Hz Auto Identification)
Resolution Rate
0.1mA
Test Precision
(23C±5C,Below 80%RH)
 
0.1mA to 299mA:        ±1%±3dgt 
300mA to 0.0A:         ±1.5%±5dgt 
0.0A to 49.9A:          ±1.5%±5dgt
50.0A to 199.9A:        ±2%±5dgt 
200A to 600A:          ±3%±5dgt   
601A to 1000A:         ±4%±5dgt   
Circuit Voltage
Test for the circuit below 23KV (operated with insulation rod)
Data Memory
99 Groups, during storage, the symbol "MEM” gives indication, "FULL” mark will flash to indicate the memory has been full.
Peak Maintenance
The function of automatic capture and maintain the maximum average value, under general test mode, press HOLD button longer till PEAK light is bright, that is, start PEAK test function, also known as peak test.
Data Preservation
Under general test mode, press HOLD button to preserve data, "HOLD” symbol display.
Data Reference
 "MR” symbol indicates, it can read the stored data by turning upwards and downwards.
Overflow Display
Exceed measurement range overflow function: "OL A” symbol display
* No signal Indicator
When the receiver has not received transmit signal, it will display "no- -”signal dynamically.
Auto Shut Down
In about 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption.
Battery Voltage
When the battery voltage is below 4.8V, the symbol of battery voltage "    ”will show to remind to replace battery.
Meter Quality
Tester: About 335g (Including battery), total quality of meter: about 2.5Kg (including insulation rod and battery.)
Work Temperature and Moisture
-10C to 40C;  Below 80%Rh
Storage Temperature and Moisture
-10C to 60C; Below 70%Rh
Insulation Rod Dimension
φ32mm, 1m/Section(5 Sections)
Insulation Intension
AC 40KV/rms (Between insulation rod and clamp core)
Structure
Anti-Dripping Type II