Manual Range Multimeter
Model: VC-9802
1.        Specification:
1.DCV
Range
Accuracy
Resolution
200mV
 
±(0.5%+3)
 
0.1mV
2V
1mV
20V
10mV
200V
100mV
1000V
±(1.0%+3)
1V
Input resistance:                    all ranges: 10MΩ
Overload protection:            200mV range: 250V DC or AC peak value,
other range: 1000V DC or AC peak value
2. ACV
Range
Accuracy
Resolution
2V
±(0.8%+5)
1mV
20V
10mV
200V
100mV
750V
±(1.2%+5)
1V
Input resistance:                   1MΩ for input range 200mV and 2V, 10MΩ for other ranges.
Overload protection:            200mV range: 250V DC or AC peak value,
other range: 1000V DC or AC peak value   
Frequency response:            lower than 200V range: 40~400Hz,
700V range: 40~200Hz
Displaying:                           rms of sine wave( mean value response)
3.DCA
Range
Accuracy
Resolution
200uA
±(0.8%+3)
0.1uA
2mA
1uA
20mA
10uA
200mA
±(1.2%+4)
100uA
20A
±(2.0%+5)
10mA
Max. measuring voltage drop:        200mV
Max. input current:                        20A(within 10 sec.)
Overload protection:                              0.2A / 250V fast-blown fuse, 20A infused.   
4. ACA
Range
Accuracy
Resolution
20mA
±(1.0%+5)
10uA
200mA
±(2.0%+5)
100uA
20A
±(2.5%+5)
10mA
Max. measuring voltage drop:         200mV
Max. input current:                        20A(ess than 10sec.)
Overload protection:                      0.2A / 250V fused, 20A range infused
Frequency response:                      40~200Hz;
Displaying:                                    rms of sine wave(mean value response)
5.Resistance(Ω)
Range
Accuracy
Resolution
200Ω
±(0.8%+5)
0.1Ω
2kΩ
±(0.8%+3)
20kΩ
10Ω
200kΩ
100Ω
2MΩ
1kΩ
20MΩ
±(1.0%+15)
10kΩ
200MΩ
±[5%(reading–10 )+ 20]
100kΩ
Open voltage:                      less than 3V
Overload protection:            250V DC or AC peak value
6. Capacitance
Range
Accuracy
Resolution
20nF
±(2.0%+20)
10pF
200nF
100pF
2uF
1nF
200uF
±(2.5%+20)
100nF
Measuring frequency:            120Hz
Overload protection:            36V DC or AC peak value
7. Diode and Continuity Test
Range
Displaying Value
Test condition
Forward voltage drop of diode
Forward DCA is approx. 1mA,backward voltage is approx. 3V
If the resistance is less than 70Ω±20Ω, buzzer sounds
Open voltage is approx. 3V
Overload protection:   250V DC or AC peak value.
Warning:                      do not input voltage at this range! 
8. Transistor hFE Data Test
Range
Displaying Value
Test condition
hFE  NPN or PNP
0 ~ 1000
Basic current is approx. 10uA , Vce is approx. 3V