Diameter:15-300mm
Accuracy:
Liquid: ±1.0% of reading
Gas: ±1.0% of reading
Vapor Stream: ±1.5% of reading
Materials:
Housing: Standard - 304 Stainless Steel
Shedder Bar: 1Cr18Ni9Ti
Converter housing and case cover: Aluminum Alloy
Output Signal: (Where applicable)
Sensor: Pulse signal (Low Level: ≤1V; High Level: ≥6V)
Transmitter: 4 to 20 mA DC current signal
Signal Transmission Distance: ≤500 m
Electrical Connections: ISO M20×1.5 Female
Explosion Proof Level:
Standard: ExdIIBT6
Protection Level: IP65
Vibration: ≤1.0 g
Ambient:
Temperature: -10℃ to +55℃
Pressure: 86 to 106 KPa
Relative Humidity: 5% to 90%
Power Supply:
Sensor: +12V DC (Optional: +24V DC)
Transmitter: +24V DC
Field Display Type: Integral 3.2V Lithium Battery or +24V DC
Fluid Temperature and Pressure:
Temperature: Standard: -20℃ to +70℃
Optional: -20℃ to +250℃; -20℃ to +350℃
Pressure: Fluid pressure should be limited according to flange rating.
Model
4.1 Vortex Flow Sensor/Transmitter
LUGB-□N Type Sensor: 12 to 24V DC Power Supply; Pulse Output
LUGB-□A Type Transmitter: 24V DC Power Supply; 2-wire 4 to 20 mA Output
Basic Type (Without Explosion Proof) and Explosion Proof Type are optional for LUGB-□N and LUGB-□A.
LUGB-□B Type: powered with 3.2V10AH lithium battery (Battery life = 4 years); no output
LUGB-□C Type: 24V DC Power Supply; 2-wire 4 to 20 mA Output (Optional: RS485)
|
Vortex Flowmeters,are a general purpose broad application instrument. Suitable for aggressive environments as they have no moving parts and offer welded corrosion-proof construction, internal sensing, modular electronics and weather tight housing, enabling them to be used on non-viscous, clean or dirty water-like liquids
They are ideal for measuring process water, water-based machine coolant, or water/glycol coolants as they can alert process operators of dangerous flow deviations. |
|
Applications for the Vortex Flowmeter include: Petroleum Chemical food Pulp and paper Metals and mining Power Water and waste treatment industries |