KH106 temperature and humidity controller is high-precision measurement and data acquisition compatible.
The controller can measure accurately and control many physical data such as temperature, humidity, pressure, liquid level, gravity, instantaneous flow and etc.
The controller adopts omnipotent input with kinds of input signals. It also adopts modern advanced modular structure output functions such as relay alarm, communication, transmission and feed etc, can be configured flexibly.
The alarm output function can be configured flexibly as high limit, low limit, higher limit, lower limit.
Modern universal MODBUS communication protocol is available, with maximum baud rate 19200 bit/s.
1. Specification
The controller can measure accurately and control many physical data such as temperature, humidity, pressure, liquid level, gravity, instantaneous flow and etc.
The controller adopts omnipotent input with kinds of input signals. It also adopts modern advanced modular structure output functions such as relay alarm, communication, transmission and feed etc, can be configured flexibly.
The alarm output function can be configured flexibly as high limit, low limit, higher limit, lower limit.
Modern universal MODBUS communication protocol is available, with maximum baud rate 19200 bit/s.
1. Specification
◆ Accuracy: ± (0. 2%FS+1)digit
◆ Sampling period: ≤ 0. 5s
◆ Power voltage: 85-240VAC
◆ T. C Cold-junction compensation :
Internal components or external CU50 compensation
◆ Power consumption: < 5W
◆ T. C. -off or over-range: display OPEN
◆ Surface Mount Technology(SMT)
Design more concise and flexible
◆ Input Signal:
T. C: K, S, E, J, T, B, N
RTD: PT100, CU50, CU100
Linear voltage: 0-5V, 1-5V
Linear current: 0-10mA, 4-20mA
Extensional specifications: customized
◆ Output Module
R1A: relay output (0. 8A NO)
R1B: relay output (0. 8A NC)
R1C: relay output (0. 8A NO+NC)
R2A: relay output (3A NO)
R2B: relay output (3A NC)
R2C: relay output (3A NO+NC)
W1: SCR contactless output (100-240VAC/0. 2A)
G: SSR slaving voltage (DC12V/50mA output)
K1: single-route SCR zero crossing trigger
K2: dual-route SCR zero crossing trigger
I1: photoelectric isolated current transmission output
S1: photoelectric- isolated RS485 communication port
S2: photoelectric- isolated RS232 communication port
U1/U2/U3: 5V/12V/24VDC isolated feed output as power supply for sensor
Eg. :order code. :KH106-D-R1C-R1A-I1-N-I-AC, basic unit. :KH106 temperature and humidity controller, size: 160 × 80 mm, two relays alarm output, current transmission output, current signal input, Power: 220VAC
As a proffesional manufacture, we can supply high quality and performance temperatu re and humidity controller, temperature controller, humidity controller, pressure controller, paperless recorder