UK series combined terminals adopt frame type screw connection structure. Complying with IEC60947-1, GB14048 standards, our terminal blocks are widely used in the circuit of AC 50Hz (60Hz), rated voltage 660V, DC 440V and below, rated sectional area 0.75~150mm2 connection conductor. It's also suitable for connecting the circle copper conductor of terminal that is not specially processed of pressure welding.
Characteristics:
Reasonable installation structure design, wide general-purpose nature, used on both G type an TH type DIN rail. If under 50mm2, it adpots fasten accessory installation.
Small size, complete set of specification, big connected conductor sectional area and good electrical conductivity. The one that is below 50 mm2 adopts copper press line frame and copper fasten screw and others adopt copper press line frame and steel screw and copper skirt plate. It has large tightening torque and self-locking function.
The strong combined function makes the connection of conductors simpler.
Characteristics:
Reasonable installation structure design, wide general-purpose nature, used on both G type an TH type DIN rail. If under 50mm2, it adpots fasten accessory installation.
Small size, complete set of specification, big connected conductor sectional area and good electrical conductivity. The one that is below 50 mm2 adopts copper press line frame and copper fasten screw and others adopt copper press line frame and steel screw and copper skirt plate. It has large tightening torque and self-locking function.
The strong combined function makes the connection of conductors simpler.
UK Terminal Block
Model
|
Hard Wire (mm2)
|
Soft Wire (mm2)
|
Rated Current
(A) |
Rated Voltage
(V) |
Dimension
(mm) |
UK2.5B
|
0.2-4
|
0.2-2.5
|
32
|
690
|
6.2 x 42.5 x 42
|
UK3N
|
0.2-4
|
0.2-2.5
|
32
|
800
|
6.2 x 42.5 x 42
|
UK5N
|
0.2-6
|
0.2-4
|
41
|
800
|
6.2 x 42.5 x 47
|
UK6N
|
0.2-10
|
0.2-2.5
|
57
|
800
|
6.2 x 42.5 x 47
|
UK10N
|
0.5-16
|
0.5-10
|
76
|
800
|
10.2 x 42.5 x 47
|
UK16N
|
2.5-25
|
4-16
|
101
|
800
|
12.2 x 42.5 x 54
|
UK35N
|
0.75-50
|
0.75-35
|
150
|
1000
|
15.2 x 50.0 x 62
|
UKH50
|
16-50
|
25-50
|
150
|
1000
|
20 x 70.5 x 83.5
|
UKH95
|
25-95
|
35-95
|
232
|
1000
|
25 x 83 x 97.5
|
UKH150
|
35-150
|
50-150
|
309
|
1000
|
31 x 100 x 118.5
|
Model
|
Hard Wire (mm2)
|
Soft Wire (mm2)
|
Rated Current
(A) |
Dimension
(mm) |
USLKG2.5
|
0.2-4
|
0.2-2.5
|
32
|
6.2 x 42.5 x 42
|
USLKG3
|
0.2-4
|
0.2-2.5
|
32
|
6.2 x 42.5 x 42
|
USLKG5
|
0.2-6
|
0.2-4
|
41
|
6.2 x 42.5 x 47
|
USLKG6N
|
0.2-10
|
0.2-2.5
|
57
|
6.2 x 42.5 x 47
|
USLKG10N
|
0.5-16
|
0.5-10
|
76
|
10.2 x 42.5 x 47
|
USLKG16N
|
2.5-25
|
4-16
|
101
|
12.2 x 42.5 x 54
|
USLKG35N
|
0.75-50
|
0.75-35
|
150
|
15.2 x 50.0 x 62
|
USLKG50
|
16-50
|
25-50
|
150
|
20 x 70.5 x 81.5
|