Function and Features
1). 2 modes: Volumetric & Drop infusion.
2). Flow rate: Drop/min, ml/h infusion volume for choice.
3). IV set: applicable to the common infusion sets, can store 6 brands of iv sets for choice.
4). Calibration: calibrate IV set according to actual situation to ensure accuracy.
5). KVO: automatic switch to KVO (Keep vein open) mode when "Over" alarm sounds.
6). Purge & Bolus function: In "Stop" state, double press "Bolus" button to rid air-in-line. During operation, single press "Bolus" button to start fast infusion.
7). Double CPU: making infusion process safer and more reliable.
8). Memory Function: Parameters which you setup last time can be saved in the machine for over 8 years.
9). Audio-visual alarms: occlusion, air-in-line, door-open, over, low battery, interruption, abnormal and delay operation.
10). AC/DC: built-in rechargeable Nickel Metal Hydrate (Ni-MH) batteries, switching from AC to DC automatically.
2). Flow rate: Drop/min, ml/h infusion volume for choice.
3). IV set: applicable to the common infusion sets, can store 6 brands of iv sets for choice.
4). Calibration: calibrate IV set according to actual situation to ensure accuracy.
5). KVO: automatic switch to KVO (Keep vein open) mode when "Over" alarm sounds.
6). Purge & Bolus function: In "Stop" state, double press "Bolus" button to rid air-in-line. During operation, single press "Bolus" button to start fast infusion.
7). Double CPU: making infusion process safer and more reliable.
8). Memory Function: Parameters which you setup last time can be saved in the machine for over 8 years.
9). Audio-visual alarms: occlusion, air-in-line, door-open, over, low battery, interruption, abnormal and delay operation.
10). AC/DC: built-in rechargeable Nickel Metal Hydrate (Ni-MH) batteries, switching from AC to DC automatically.
|
Mode of infusion |
Volumetric & Drop infusion (rate mode, drop mode) |
Power supply |
AC: 220V±22V 50Hz±1Hz DC: 9.6V±1.6V |
||
| Dimension | 160×126×215mm | Battery | Rechargeable lithium polymer battery, 7.4V, 1600mA | ||
| Weight | About 2.2kg | ||||
| Applicable IV set | Open system: all Micro and Macro IV sets of national standard. (can store 6 brands of iv sets for choice) | Fuse | 220V 2A*2, 12V 2A*2 | ||
| Electrical safety | Comply with the stipulation of GB9706.1-1995, EN60601-1 and UL60601-1 | ||||
| Accuracy | ±5% | Battery recharge | It charges automatically if the batteries are nearly used up, (Have to charge more than 8 hours continuously). When the battery power is used up, it gives alarm and notices the users to handle it. | ||
| Flow rate | 1ml/h ~1100ml/h, 1ml/h step | ||||
| Preset volume limit | 1ml~9999ml, 1ml increment | ||||
|
Purge & Bolus function |
In “Stop” status, press “Bolus” key to start Purge function. In “Running” status, press “Bolus” key to start Bolus function. | Maximum power consumption | Less than 20VA | ||
| Battery running hour | More than 3 hours continuously at 30ml/h with fully charged battery. | ||||
|
Displayed information |
Rate, volume limit, accumulated volume, Infusion set brand, sensitivity, | ||||
| Operating conditions |
Environment temperature: 10ºC~30ºC Relative humidity: 30%~75% Atmospheric pressure: 860 hPa ~ 1060hPa |
||||
|
KVO flow rate |
4ml/h |
||||
| Storage and transport conditions | Environment temperature -15 ºC~+50ºC , atmosphere pressure 86~106kPa, relative humidity20%~90%. | ||||
| Occlusion sensitivity | Adjustable | ||||
| Alarm function | Occlusion, air-in-line, over, empty, door open, low battery, interruption, abnormal, delay operation |
Classification |
Class I , Type BF |