■ Product Standard
IEC 60092-350, IEC 60092-354, IEC 60332-3-22, IEC 60754, IEC 61034
■ Application
The cable is intended for ships, petrol platforms and offshore buildings to transmit medium voltage power.
No. of cores
×nominal cross- sectional area (mm²) |
CYJ86/SC 3.6/6 KV
|
CYJ86/SC 6/10 KV
|
CYJ86/SC 8.7/15 KV
|
||||||
Calculated diameter
(mm) |
Calculated
mass (kg/km) |
Calculated diameter
(mm) |
Calculated
mass (kg/km) |
Calculated diameter
(mm) |
Calculated
mass (kg/km) |
||||
nom.
|
max.
|
nom.
|
max.
|
nom.
|
max.
|
||||
1×10
|
19.3
|
21
|
641
|
-
|
-
|
-
|
-
|
-
|
-
|
1×16
|
20.4
|
22
|
743
|
22.3
|
24
|
846
|
-
|
-
|
-
|
1×25
|
21.8
|
23.5
|
888
|
23.7
|
25.5
|
995
|
26.1
|
28
|
1136
|
1×35
|
23.2
|
25
|
1043
|
25.1
|
27
|
1155
|
27.5
|
29.5
|
1301
|
1×50
|
24.5
|
26.5
|
1240
|
26.4
|
28.5
|
1356
|
28.8
|
31
|
1508
|
1×70
|
26.4
|
28.5
|
1514
|
28.4
|
30.5
|
1637
|
30.7
|
33
|
1796
|
1×95
|
28.5
|
30.5
|
1840
|
30.4
|
32.5
|
1970
|
32.8
|
35
|
2138
|
1×120
|
30.2
|
32.5
|
2153
|
32.1
|
34.5
|
2289
|
34.5
|
37
|
2464
|
1×150
|
31.3
|
33.5
|
2481
|
33.2
|
35.5
|
2621
|
35.6
|
38
|
2800
|
1×185
|
33.9
|
36.5
|
2931
|
35.8
|
38.5
|
3079
|
38.7
|
41.5
|
3381
|
1×240
|
36.8
|
39.5
|
3584
|
39.3
|
42
|
3855
|
41.6
|
44.5
|
4065
|
1×300
|
40
|
43
|
4324
|
41.9
|
44.5
|
4557
|
44.2
|
47
|
4778
|
3×10
|
35
|
37.5
|
1536
|
-
|
-
|
-
|
-
|
-
|
-
|
3×16
|
37.8
|
40.5
|
1933
|
41.9
|
44.5
|
2224
|
-
|
-
|
-
|
3×25
|
40.8
|
43.5
|
2353
|
44.8
|
48
|
2660
|
50.3
|
53.5
|
3082
|
3×35
|
43.7
|
46.5
|
2806
|
47.8
|
51
|
3129
|
53.2
|
56.5
|
3570
|
3×50
|
46.4
|
49.5
|
3389
|
50.9
|
54
|
3743
|
55.9
|
59.5
|
4187
|
3×70
|
50.9
|
54
|
4217
|
55
|
58.5
|
4577
|
60
|
64
|
5048
|
3×95
|
55.2
|
59
|
5191
|
59.3
|
63
|
5575
|
64.3
|
68.5
|
6074
|
3×120
|
58.9
|
62.5
|
6128
|
63
|
67
|
6532
|
68
|
72
|
7056
|
3×150
|
61.1
|
65
|
7121
|
65.2
|
69
|
7537
|
70.2
|
74.5
|
8076
|