Washer-type Load Cell
Technical Parameter:
Rated Load:
|
10/20/30t
|
Sensitivity:
|
(1.5±0.1%) mV/V
|
Combined Error:
|
±2% F.S
|
Creep Error(30min):
|
±0.5% F.S
|
Zero Balance:
|
±1% F.S
|
Temp. Effect On Zero:
|
±0.05% F.S/10℃
|
Temp. Effect On Span:
|
±0.05% F.S/10℃
|
Input Resistance:
|
750±5Ω
|
Output Resistance:
|
701±2Ω
|
Insulation Resistance:
|
≥5000MΩ
|
Operating Temperature Range:
|
-30~+70℃
|
Maximum Safe Over Load:
|
150%F.S
|
Ultimate Over Load:
|
250%F.S
|
Recommend Excitation Voltage:
|
10~12V DC
|
Maximum Excitation Voltage:
|
15V DC
|
Sealing Class:
|
IP65
|
Element Material:
|
Alloy Steel, Stainless Steel
|
Cable:
|
Length=L:12m
|
Citation:
|
GB/T7551-1997/ OIML R60
|
Mode Of Connection:
|
Red(Input+),Black(Input-),Green(Output+),White(Output-)
|