Product Main

Specifications


1. Model No.: AK-200FC/C7
2. Gas detected: Carbon monoxide
3. Size: 163mm*87mm*40mm
4. Working voltage: AC220V/AC110V, 12VDC-20VDC
5. Backup battery: 9V ordinary alkaline battery
6. Additional function: can work with solenoid valve or exhaust fan
7. Wired network connection function: (NO, NC)
8. Wireless networking model: 315MHZ/433MHZ   (2262 OR 1527)
9. Patent No.: 200830103202.4
10. Options of gas density and alarm level:
EN (EN50291):
Density (PPM)
50
100
300
400
Reaction time (minutes)
60 -90
10 -40
Less than 3
Immediately
CN (CHINA):
Density (PPM)
More than 150
Reaction time (Seconds)
5