Description of Thermal Relay (CXR2-D23)

CXR2 series overload relay applies to circuit of AC 50Hz or 60Hz, rated voltage to below 660V and rated current 0.1A~93A for AC motor overload and open-phase protection during long time or intermittent long time service, can also protect 3-phase erious imbalance and long starting time of motor or long time operation, can also be sed for orresponding AC contactor for electromagnetic starter.
This product has innovative, elegant model and small installation area, functions uch as temperature compensation, action indication, automatic and manual reset, top with steady and reliable performance.
Thermal relay can be combined/connected with contactor or installed separately.
Standard: IEC60947-4-1