Features of Truck scale:
1. Able to connect with digital load cell
2. Auto/manual angle correction
3. With correction mode for static railway scale
4. Digital load cell communication address modification function
5. Single load cell and single angle data check function
6. Call and display inner code to replace weight observing and analysis tolerance
7. Able to set up zero-tracking range, zero (auto/manual) range
8. With bi-divisions switch function
9. Non-linearity correction and calibration tolerance correction
10. Time power-off function
11. Able to set up print function for fast filled weighing bill
12. Weighing data save/check/delete/protection in case of power off
13. Standard RS232C (RS422/RS485 optional) communication interface with selectable baud rate
14. Standard scoreboard interface with 20mA current loop method
15. Standard parallel print interface
16. Able to save 1500 vehicle ID and corresponding tare weight, 201 cargo ID and corresponding cargo name, 1001
17. Able to print out various parameters of indicator
| Main technical Parameters for load cell | ||||
| Capacity | 10, 20, 25, 30 | T | ||
| Sensitivity | 2.0±0.004 | MV/V | ||
| Accuracy class | C3 | C2 | 0.05 | |
| Max number of load cell interval | 3000 | 2000 | ||
| Min load cell verification interval | Emax /10000 | Emax /7000 | ||
| Combined error | 0.02 | 0.023 | 0.05 | %F. S. |
| Repeatability | 0.01 | 0.015 | 0.03 | %F. S. |
| Creep | ±0.0245 | ±0.0245 | ±0.05 | %F. S. / 30min |
| Min dead load output return | ±0.017 | ±0.025 | ±0.05 | %F. S. |
| Temp. effect on min. dead load output | ±0.007 | ±0.010 | ±0.025 | %F. S. / 5 |
| Temp. effect on sensitivity | ±0.007 | ±0.009 | ±0.025 | %F. S. / 5 |
| Min dead load | 1 | %Emax | ||
| Max safe overload | 150 | %Emax | ||
| Ultimate overload | 200 | %Emax | ||
| Max transmission distance | ||||
| Supply voltage | 10 ~ 15 ( DC/ AC) | V | ||
| Zero balance | ±1 | %F. S. | ||
| Input resistance | 770 ~ 830 | Ω | ||
| Output resistance | 697 ~ 706 | Ω | ||
| Insulation resistance | ≥ 5000 | MΩ | ||
| Protection class | IP68 | |||
| Compensated temperature range | -10 ~ +40 | |||
| Operating temperature range | -30 ~ +70 | |||
| Connect cable | 6.7 * 15000 | mm | ||
| Method of connecting wire | Input(+): Red Input(-): White | |||
| Output(+): Green Output(-): Blue | ||||
| Shield: Yellow | ||||
| SCS-100 Specifications | |
| Max Capability (T) | 100 |
| Graduation (Kg) | 20 |
| Platform size (m) | 3.0×15 (16, 18, 20) |
| 3.2×16 (18, 20) | |
| 3.4×16 (18, 21) | |
| Number of modules | 3 |
Standard parts of Truck scale
Load cell: 8 or 10 sets
Indicator: 1 set
Cable: 30m
Selective parts of Truck scale
Computer: 1 set
Printer: 1 set
Ramp: 1 or 2 sets
Guardrail: 2 sets