Standard Configuration: ECG, SPO2, NIBP, HR, TEMP, RESP.
Optional: EtCO2, Battery, Recorder.
Features
· 7″ color TFT display with touch screen.
· Full-lead ECG monitoring.
· Touchscreen provides the superior flexibility required for patient management.
· Built-in 3 trace thermal recorder for printing real-time and historical data.
· Select from either Sidestream or Mainstream EtCO2 technology to obtain fast, simple, and accurate CO2 results for intubated or non-intubated patients.
· Large font display, 2 waveforms and 3 waveforms for selecting.
· Networkable with Central Monitoring System via a wireless or wired network.
· Multi-lingual selectable, can be used in a majority of countries in the world.
· NIBP list display.
· Built-in battery.
· ST Analysis, Arrhythmia analysis.
· Pitch tone.
· Data manager function.
· 74 hours trend data analysis.
Specifications
Application
|
|
Neonatal, pediatric and adult patients
|
|
Physical Dimensions & Weight
|
|
Base Unit:
|
229(W)×133(D)×210(H)mm
|
Weight:
|
2.5kgs
|
Peformance Specifications
|
|
Display:
|
7.0 inch (Diagonal) color TFT
|
Resolution:
|
800 × 3(RGB) × 480
|
Trace:
|
2 or 3 waveforms
|
Waveforms
|
ECG(I, II, III, aVR, aVL, aVF, V1-V6), PLETH, ETCO2
|
Indicator:
|
Alarm indicator
Power indicator
QRS beep and alarm sound
|
Trend time:
|
From 1 to 48 hours
|
Recorder:
|
Built-in, thermal array, 2 channels
Record width: 48mm
Recorder paper: 50mm
Record speed: 25mm/s, 50mm/s
|
AC Power:
|
100~240VAC, 50/60Hz, <150VA
|
Battery:
|
Rechargeable Lead-Acid
Operating time: 2 hours
|
ECG
|
|
Input:
|
5-lead ECG cable and standard AAMI line for connection
|
Lead Choice:
|
I, II, III, aVR, aVF, aVL, V
|
Gain Choice:
|
×0.5, ×1.0, ×2.0
|
Frequency Characteristic:
|
0. 5~40 Hz (+3dB)
|
ECG Waveforms:
|
7 channels
|
Penetration Voltage:
|
4000VAC 50/60Hz
|
Sweep Speed:
|
12.5, 25 and 50 mm/s
|
HR Display Range:
|
30~300bpm
|
Accuracy:
|
±2bpm
|
Alarm Limit Range
|
Upper limit:80~400bpm
Lower limit: 20~150bpm
|
RESPIRATION
|
|
Measure Method:
|
RA-LL impedance
|
Range:
|
0~120 rpm
|
Accuracy
|
+ 3 rpm
|
Alarm Upper-lower Limit
|
Upper limit: 6~120 rpm,
Lower limit: 3~120 rpm
|
Sweep Speed:
|
12.5 and 25mm/s
|
NIBP
|
|
Measuring Technology:
|
Automatic oscillating measurement
|
Cuff Inflating:
|
<30s(0~300 mmHg, standard adult cuff)
|
Measuring Period:
|
AVE<40s
|
Mode
|
Manual, Auto, STAT
|
Measuring Interval in AUTO Mode
|
2 min~4 hrs
|
Pulse Rate Range:
|
30 bpm~250 bpm
|
Measuring Range:
|
Adult/Pediatric Mode
SYS 40~250 (mmHg)
DIA 15~200 (mmHg)
Neonatal Mode
SYS 40~135 (mmHg)
DIA 15~100 (mmHg)
|
Resolution:
|
1mmHg
|
Pressure Accuracy:
|
Maximum Mean error: ±5mmHg
Maximum Standard deviation: 8mmHg
|
Overpressure Protection:
|
Adult Mode 280(mmHg)
Neonatal Mode 150 (mmHg)
|
Alarm Limit:
|
SYS 50~240 mmHg
DIA 15~180 mmHg
|
TEMPERATURE
|
|
Range:
|
25~50(℃)
|
Accuracy:
|
+ 0.2℃(25.0~34.9℃)
+ 0.1℃(35.0~39.9℃)
+ 0.2℃(40.0~44.9℃)
+ 0.3℃(45.0~50.0℃)
|
Display Resolution:
|
0.1℃
|
Alarm Upper-lower Limit:
|
Upper limit 0~50℃,
Lower limit 0~50℃
|
Alarm Limit:
|
10~50(℃)
|
SPO2
|
|
ASpO2:
|
Anti-motion SpO2
|
SpO2% Range:
|
0~100%
|
SpO2 Accuracy:
|
+ 2%(70~100%,non-motion)
+ 3%(70~100%, motion)
|
Pulse Rate Range:
|
30-250 bpm
|
Pulse Rate Accuracy:
|
±2 bpm(non-motion)
±3 bpm (motion)
|
Alarm Upper-lower Limit:
|
Upper limit 70~100%,
Lower limit 70~100%
|
SpO2 Probe:
|
Red light LED wavelength 660nm±5nm
Infrared light LED wavelength 940nm±10nm
|
EtCO2(OPTION)
|
|
Mode of Sampling:
|
Sidestream or Mainstream
|
Principle of Operation:
|
Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts.
|
CO2 measurement Range:
|
0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa)
|
CO2 Calculation Method:
|
BTPS (Body Temperature Pressure Saturated)
|
CO2 Resolution:
|
0.1mmHg(0-69mmHg), 0.25mmHg(70-150mmHg)
|
CO2 Accuracy:
|
0~40 mmHg ± 2 mmHg
41~70 mmHg ± 5% of reading
71~100 mmHg ± 8% of reading
101~150 mmHg ± 10% of reading
Above 80 breath per minute ± 12% of reading
|
Sampling rate:
|
100Hz
|
Respiration Rate:
|
2~150 bpm
|
Respiration Rate accuracy:
|
±1 breath
|
Response Time:
|
<3 seconds - includes transport time and rise time
|
Inspired CO2 measurement Range:
|
3~50 mmHg
|
Networking
|
|
Wired Networking
|
Industry standard: 802.11b/g wired network
Frequency Range: 2.412~2.484 GHz
Connected bedside number: Up to 16 bedside monitors
|
Wireless Networking
|
Up to 100m indoors
Industry standard 802.11b/g wireless
Supports TCP/IP and UDP/IP Protocols
|
Power
|
|
Source:
|
External AC power or internal battery
|
AC Power:
|
100~240VAC, 50/60Hz, 60VA
|
Battery:
|
Built-in and lithium Ion rechargeable, 12.6V/5Ah
|
Charge Time:
|
8 hours
|
Operating Time:
|
3 hour
|
Environmental Specifications
|
|
Temperature:
|
Operating: 5~40 °C
Storage: -10~45 °C
|
Humidity Range:
|
Operating: ≤80 %
Storage: ≤80 %
|
Recorder (Option)
|
|
Record Width:
|
48 (mm)
|
Paper Speed:
|
25 (mm/s)
|
Trace:
|
2
|
Fuse
|
3.15A/250V
|
LCD Specifications
|
|
Display Type:
|
TFT color LCD
|
Size (diagonal):
|
7.0 inch
|
Active Area:
|
152.4 (W) × 91.44 (H) mm
|
Color arrangement:
|
RGB-stripe
|
Dot pitch:
|
0.0635(W) × 0.1905(H) mm
|
Display Mode:
|
Normally white, Transmissive
|
Interface:
|
Digital(TTL)
|
Surface Treatment:
|
Anti-Glare
|
Touchscreen Specifications
|
|
Type:
|
Four-Wire Analog Resistive Touch Panel
|
Input Mode:
|
Stylus Pen or Finger
|
Connector:
|
FPC
|
Insulation resistance:
|
25MΩ
|
Voltage:
|
7VDC
|
Chattering:
|
10ms
|
Transparency:
|
80%
|
Surface hardness:
|
3H
|
Durability-surface scratching:
|
Write
100,000
|
Active force:
|
80gf
|
Knock Test:
|
1,000,000 times
|