C. Notes and operation environment
(1).The unit should be placed on stable location, right and left should keep over 10cm away from apyrous object. The backside should be over 20cm away from apyrous object.
(2).The user should install primary disconnecting device and leakage protection whose off-contact is over 3mm in fired power switch before using. The other object cannot be put around the switch for safe operation.
(3).The voltage of power should be the same as the one on nameplate of the unit. The difference cannot beyond +10%.
(4).The earth wire in the unit ( the yellow and green wire) leaded out with power wire should be connected with earth wire (which is ) measured up safely in power
line unfailingly. .
(5).The equipotential grounded circuit is set in the backside of the unit, the copper wire is not less than 2.5mm2 can be used for connection with earth wire which is measured up safely.
Warning: it is strictly forbidden to connect the earth wire with water pipe, gas pipe, central heating pipe and so on, or else it will cause security accidents.
(6).If the mains cord broken, it must be replaced by model “YCW “or “YZW “oil-proof cable with yellow and green earth wire which is the same specification as the broken one.
(7).All the electricity connection and installation should be done by qualified electrician.
(8)This equipment is not equipped to be used by unwell, unresponsive or mentally disturbed people, including children, unless under the guidance or help of persons who are responsible for their security. Keep an eye on children and keep them away from playing around the equipment.
Warning: The temperature of the unit is rising while it is working, it is forbidden to touch! In case any accident caused by spilling out the oil, please keep children away from the unit.
Warning: It is strictly forbidden that the heating element or heating plate works without any liquid immersed. If any damage caused by such situation, it’s beyond warranty service.